Carlisle Fluid Technologies E2-30/E2-40 Electric Pump Service Manual

The E2-30/40 electric pump user manual introduces the features and specifications of the product.


Carlisle Fluid Technologies E2-30/E2-40 Electric Pump Service Manual - cover page
Brand
Carlisle Fluid Technologies
Category
Other products
Document type
Service Manual
Language
Chinese
Pages
40
File format
PDF
File size
5.6 MB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
2B4C5EE763B6E7FA0D4738DAE8D505DA

About this manual

This is the Chinese-language service manual (document 77-3215 R5.5) for the Carlisle Fluid Technologies E2-30 and E2-40 electric pumps. It covers part numbers 107075/107074/107071 for the E2-30 (Japan/US/EU models) and 107095/107094/107093 for the E2-40 (Japan/US/EU models). The manual contains safety warnings, an EU declaration of conformity, technical specifications, dimensions and installation details, operating instructions, and a parts list with accessories.

The pumps are designed for use in ATEX Category 2 Zone 1 hazardous areas and are offered with EU (400 V), US (460 V) and Japan motor variants. The manual explains gearbox oil requirements, pressure switch and pressure relief valve settings, required inverter settings, manifold and PRV assemblies, and accessories such as the BPR control box, pressure sensor and grease guns for the linear bearings and cam follower. This manual is written in Chinese.

What's inside

  • Safety warnings
  • EU Declaration of Conformity
  • Specifications
  • Dimensions and installation details
  • Installation
  • System operation
  • Parts list - pump assembly
  • Accessories

Specifications

Max fluid pressure (E2-30 / E2-40)16 bar [232 psi] / 20.7 bar [300 psi]
Max input pressure2 bar [29 psi]
Nominal stroke50 mm [1.97 ins]
Gearbox reduction ratio56:1
Total pump weight (with electric motor)250 kg [550 lbs]
Motor (EU model)400 V 3PH, 1.5 kW @ 50 Hz
Motor (US model)460 V 3PH, 1 Hp @ 60 Hz
Motor (Japan model)0.75 kW, 4-pole, 1400 RPM
Rated frequency range20 to 80 Hz (with thermistor)

Frequently asked questions

What gearbox oil should be used in the E2-30/E2-40 pump?

EU models use synthetic oil 220 (typically Agip Blasia S), while US models use SHC 630 synthetic oil. The gearbox is supplied filled with the correct amount of oil.

How should the pressure switch be set?

The maximum pressure switch settings are 20 bar [305 psi] and 17 bar [246 psi], and it is recommended to set the switch 1 bar [14.5 psi] above the maximum required pressure.

In which hazardous areas can the pump be used?

The pump unit is designed for use in ATEX Category 2 Zone 1 hazardous areas, and electrical connections must comply with local regulations for hazardous-area installation.

What inverter output frequency is required for the motor?

The inverter must have a minimum output frequency of 20 Hz and a maximum output frequency of 80 Hz, with a 5-second acceleration time and 0.1-second deceleration time.

Download PDF (5.6 MB)

More Carlisle Fluid Technologies Manuals


View all Carlisle Fluid Technologies manuals →