About this manual

This is the daily maintenance manual (document number ZL-GR-002-V1, published January 2020) for the GR series painting robots of CMA Hime (Wuhu) Robot Technology Co., Ltd. It is intended for operators, maintenance staff and service technicians, and applies to all GR series painting robots sold by CMA.

The manual describes the required daily upkeep: the recommended operating environment, wearing and replacing protective suits, cleaning the robot body with emphasis on the wrist, spray gun and gun holder, and cleaning the control cabinet and teach pendant. It is one volume of a full manual set that also includes safety, explosion-proof use, remote assistance, IO communication, software programming and mechanical/electrical maintenance manuals. This manual is written in Chinese.

What's inside

  • 机器人使用环境
  • 机器人本体日常清洁维护
  • 机器人防护服的穿戴
  • 机器人本体的清洁保养
  • 机器人电控柜日常清洁维护
  • 电控柜的清洁
  • 示教器的清洁

Specifications

Operating environment temperature0°C to 40°C
Operating environment humidity20–95HR, non-condensing
Installation base vibrationLess than 0.5g
Purge air pressure (explosion-proof body)6–8 bar
Purge air flow900–1100 L/min
Purge air cleanlinessParticles smaller than 5 μm
Filter cotton replacement intervalEvery 500 hours (recommended)

Frequently asked questions

How often should the robot protective suits be replaced?

The base and upper-arm suits should be replaced monthly, the process-arm protection weekly, and the wrist suit daily, adjusted according to actual contamination.

What solvent can be used to clean the robot wrist?

Use a lint-free cloth with cleaning agent, but strong corrosive solvents such as acetone must not be used; apply vaseline afterwards.

Can compressed air be used to clean inside the control cabinet?

No, never blow the inside of the control cabinet directly with compressed air, and the power must be cut off before cleaning the controller interior.

How often should the robot body be cleaned?

Cleaning and maintenance of the robot body is recommended once per day to keep the robot in good condition.