The B140 Dynamic Brake Technical Manual describes the features and benefits of the B140 Dynamic Brake, including its comprehensive technical support program, focus on quality, and electromagnetic compatibility (EMC) and safety.
The B140 is the main power switching element in a dynamic braking system for Elite Series AC motor controllers. It allows controllers to handle large-inertia or regenerative loads by converting regenerative energy into heat in dynamic braking resistors, and can switch up to 300 A at up to 735 Vdc into a resistive load, with up to 220 kW per unit.
The manual covers electrical specifications and technical data, unpacking, installation and connections, application suggestions, EMC and safety, and commissioning guidance. It states that the B140 provides functional braking rather than safety braking, requires correct gland plate and cover installation for IP20 protection, and must be mounted vertically with specified clearances. This manual is written in Chinese.
| Dynamic braking switch voltage | 390 Vdc or 735 Vdc |
|---|---|
| Maximum switching current | 300 A (R = 2.4 Ω at 735 Vdc) |
| Continuous current rating | 140 A (R = 5.2 Ω at 735 Vdc) |
| Minimum resistance rating | 2.4 Ω |
| Maximum regenerative energy per unit | 220 kW |
| Braking voltage control mode | Slave (external controller) or master (internal sensing circuit) |
| Fault relay output | Normally closed; opens on fault or no power; non-latching |
| Slave DB control output | 13 mA current output |
| Protection rating | IP20 |
| IGBT heatsink trip temperature | 90 °C |
| Resistor overheat protection | Configurable for external resistor overheat |
| Operating temperature | 0 to 50 °C |
| Relative humidity | 80% at 31 °C to 50% at 50 °C |
| Storage temperature | 25 to 80 °C |
| Altitude | 1000 m; derate 1% per 100 m above 1000 m, maximum 3000 m |
| Pollution degree | 2 (non-corrosive environment) |
| Dimensions | 387 × 154.5 × 189.5 mm |
| Maximum cable length to Elite Series | 2 m |
| Maximum cable length to resistor | 20 m |
| Mounting fasteners | 4 × M5 with washers |
| Power terminal fasteners | 4 × M8×25 with bolts, nuts and washers |
It is used in a dynamic braking system that allows Elite Series AC motor controllers to handle large-inertia or regenerative loads.
The B140 can switch up to 300 A at up to 735 Vdc into a resistive load.
Each B140 can switch up to 220 kW of regenerative energy.
No. It provides functional braking and is not safety braking; a separate mechanical safety brake must be used where required.
A vertical clearance of 150 mm and a horizontal clearance of 50 mm from other equipment are required.