PDL Electronics B140 Dynamic Brake Technical Manual

The B140 Dynamic Brake Technical Manual describes the features and benefits of the B140 Dynamic Brake, including its comprehensive technical support program, focus on quality, and electromagnetic compatibility (EMC) and safety.


PDL Electronics B140 Dynamic Brake Technical Manual - cover page
Brand
PDL Electronics
Category
Other device
Document type
Installation Guide
Language
Chinese
Pages
20
File format
PDF
File size
1.5 MB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
FA8637DE8E0F3B4A89D1F4762867E94C

About this manual

The B140 is the main power switching element in a dynamic braking system for Elite Series AC motor controllers. It allows controllers to handle large-inertia or regenerative loads by converting regenerative energy into heat in dynamic braking resistors, and can switch up to 300 A at up to 735 Vdc into a resistive load, with up to 220 kW per unit.

The manual covers electrical specifications and technical data, unpacking, installation and connections, application suggestions, EMC and safety, and commissioning guidance. It states that the B140 provides functional braking rather than safety braking, requires correct gland plate and cover installation for IP20 protection, and must be mounted vertically with specified clearances. This manual is written in Chinese.

What's inside

  • Important notes
  • Introduction
  • Electrical specifications and technical data
  • Unpacking, installation and connection
  • Application suggestions
  • EMC and safety
  • Commissioning guidance
  • Maintenance

Specifications

Dynamic braking switch voltage390 Vdc or 735 Vdc
Maximum switching current300 A (R = 2.4 Ω at 735 Vdc)
Continuous current rating140 A (R = 5.2 Ω at 735 Vdc)
Minimum resistance rating2.4 Ω
Maximum regenerative energy per unit220 kW
Braking voltage control modeSlave (external controller) or master (internal sensing circuit)
Fault relay outputNormally closed; opens on fault or no power; non-latching
Slave DB control output13 mA current output
Protection ratingIP20
IGBT heatsink trip temperature90 °C
Resistor overheat protectionConfigurable for external resistor overheat
Operating temperature0 to 50 °C
Relative humidity80% at 31 °C to 50% at 50 °C
Storage temperature25 to 80 °C
Altitude1000 m; derate 1% per 100 m above 1000 m, maximum 3000 m
Pollution degree2 (non-corrosive environment)
Dimensions387 × 154.5 × 189.5 mm
Maximum cable length to Elite Series2 m
Maximum cable length to resistor20 m
Mounting fasteners4 × M5 with washers
Power terminal fasteners4 × M8×25 with bolts, nuts and washers

Frequently asked questions

What is the B140 used for?

It is used in a dynamic braking system that allows Elite Series AC motor controllers to handle large-inertia or regenerative loads.

What is the maximum switching current and voltage of the B140?

The B140 can switch up to 300 A at up to 735 Vdc into a resistive load.

How much regenerative energy can one B140 switch?

Each B140 can switch up to 220 kW of regenerative energy.

Is the B140 a safety brake?

No. It provides functional braking and is not safety braking; a separate mechanical safety brake must be used where required.

What clearances are required when installing the B140?

A vertical clearance of 150 mm and a horizontal clearance of 50 mm from other equipment are required.

Download PDF (1.5 MB)