The manhole cover status monitor is a device used to monitor the status of the manhole cover. It is installed on the back of the manhole cover. When the manhole cover moves, tilts and reaches the alarm trigger condition, it will trigger the manhole cover monitor alarm and send the alarm signal to the monitoring center through wireless transmission. The monitoring center parses the data and judges the alarm situation.
The StarWSN SJ200-N is a manhole cover status monitor designed to detect cover movement and tilt. It uses NB-IoT wireless communication to send alarm signals to a monitoring center when the cover tilts beyond a set threshold. The device is battery-powered, features an IP68 protection rating, and is constructed from PC+ABS materials for durability. This manual is written in Chinese.
| Communication Method | NB-IOT |
|---|---|
| Frequency Band | B5 850Mhz |
| Operating Voltage | 3.6V |
| Working Current | <350mA |
| Standby Current | <19μA |
| Battery Capacity | 8.5Ah |
| Operating Temperature | -40~+85℃ |
| Angle Measurement Range | 0°~180° |
| Angle Measurement Accuracy | ± 2° |
| Response Time | ≤5 秒 |
| Protection Rating | IP68 |
| Dimensions | 119.65×40mm |
The alarm angle threshold can be configured to 20, 30, 45, 60, or 90 degrees.
The device sends an alarm information via wireless network to the monitoring center.
Possible causes include the NB-IoT module not being registered, low battery, or the SIM card being out of credit or having data services disabled.