The Visatron® VN2020 oil mist detector is a device used to detect oil mist. It can be installed in various industrial environments, such as power plants, refineries and chemical plants. The device can detect the concentration of oil mist and issue an alarm when the concentration reaches a dangerous level.
These operating instructions describe the Visatron VN2020 and VN2020 Ex oil mist detectors manufactured by Schaller Automation Industrielle Automationstechnik GmbH & Co. KG of Blieskastel, Germany. The detectors protect large gas, diesel and dual-fuel engines against oil mist explosions in the crankcase and form part of a safety system that protects personnel and prevents severe consequential damage. They were developed in accordance with IACS UR M10 and work on the venturi principle, continuously drawing crankcase atmosphere through an optical measuring section so that the time between oil mist formation and alarm is short.
The manual covers the detector system and its components — detector, bracket, sampling lines, engine wall plate connection with suction funnels, siphon assembly, hoses and siphon bottle — as well as safety measures, installation, initial commissioning, operation with displays and fault codes, maintenance and repair work, spare parts lists and accessories. Technical data includes a supply voltage of 18–31.2 V DC, a compressed air supply of 2–14 bar, an operating temperature range of 5–70 °C and protection class IP 54. This manual is written in Chinese.
| Dimensions | approx. 539 x 298 x 171 mm |
|---|---|
| Weight | 12.41 kg |
| Supply voltage | 18 – 31.2 V DC, rated 24 V DC |
| Current consumption | max. 2 A |
| Compressed air supply | min. 2 bar, max. 14 bar |
| Compressed air consumption | 1.2 nm³/h ± 10% |
| Negative pressure | min. -55 mmWs (-5.5 mbar), nominal -60 mmWs (-6 mbar), max. -65 mmWs (-6.5 mbar) |
| Operating temperature | 5 to 70 °C |
| Storage temperature | -25 to 80 °C |
| Protection class | IP 54 |
| Communication interface | 3-wire RS485, electrically isolated / CANopen, electrically isolated |
| Air quality | ISO 8573-1:2010 - 6-4-4 |
| Relay outputs | 2 × High Oil Mist Alarm, 1 × Ready, 1 × Oil Mist Pre-Alarm; max. 60 V AC/DC, 1 A |
It protects large gas, diesel and dual-fuel engines from oil mist explosions in the crankcase as part of a safety system that protects personnel and prevents severe consequential damage.
The VN2020 for areas without explosion hazard according to ATEX, and the VN2020 Ex for hazardous areas according to ATEX / IECEx.
It works on the venturi principle, continuously drawing crankcase atmosphere through an optical measuring section so that the response time between oil mist formation and alarm is short.
A 3-wire RS485 interface and CANopen, both electrically isolated.