This manual introduces the maintenance methods of RA021 series tractor brakes.
This document is a maintenance manual for the Fujitec RA021 series brake, designed for use with traction machines in elevators. It outlines safety protocols, structural details, and specific procedures for maintaining the brake electromagnet and related components. The guide is intended for qualified personnel with relevant certification who are responsible for the installation and maintenance of elevator systems. This manual is written in Chinese.
| Maintenance Interval | Every 800,000 operations or 12 months |
|---|---|
| Basic Check Interval | Every 1 month |
| Brake Liner Minimum Thickness | 6mm |
| Recommended Lubricant | Molybdenum Disulfide (Super Longterm grease or SL3145 or SL3330SL3301) |
The electromagnet should be disassembled every 800,000 operations or 12 months, whichever comes first.
The manual recommends using Molybdenum Disulfide, specifically Super Longterm grease, SL3145, SL3330, or SL3301.
The brake liner thickness must not be less than 6mm.