The FM12-M6/M8 portable ultrasonic flowmeter is designed based on the time difference time measurement principle. The product adopts digital technology and low-voltage integrated circuit design, with wideband pulse transmission function. It is mainly used for full pipe and single clean liquid applications. It has good tolerance to liquids containing a small amount of bubbles or suspended solids in most industrial environments, ensuring measurement stability.
This is the Chinese user manual (使用说明书, v1.0) for the Feejoy FM12-M6 and FM12-M8 portable ultrasonic flowmeters. The instruments are transit-time (时差式) ultrasonic flowmeters intended for full pipes and single clean liquids, and are used for online verification and patrol measurement of liquid flow in water treatment, water plants, chemical, irrigation and industrial process water applications.
The manual describes the technical parameters, product composition, applications, operation and precautions for both models. The FM12-M6 covers pipe diameters of 25–2000 mm with ±1.0% accuracy, while the FM12-M8 covers 25–5000 mm with ±0.5% accuracy. It also explains the V, N, Z and W sensor mounting methods, installation site selection, dimensions, and ordering codes. This manual is written in Chinese.
| Flow range | 0~±12 m/s (0~±40 ft/s) |
|---|---|
| FM12-M6 flow accuracy | ±1.0% of measured value |
| FM12-M8 flow accuracy | ±0.5% of measured value |
| FM12-M6 pipe diameter range | 25 mm ~ 2000 mm (1–80 inches) |
| FM12-M8 pipe diameter range | 25 mm ~ 5000 mm (1–200 inches) |
| Outputs | 4–20 mA (max load 750 Ω), OCT pulse output 0~9999 Hz (M6); 4–20 mA (M8) |
| Power supply | Built-in lithium battery (16 h) |
| Display | M6: 2.8" TFT LCD 320*240; M8: 3.5" TFT LCD 480*320 |
| Operating temperature | Converter -40℃~60℃; sensor -40℃~80℃ (standard) |
| Weight | Converter approx. 0.82 kg; sensor approx. 1.29 kg (standard) |
| Protection rating | IP54, CNC-machined aluminum alloy housing |
| Sensor cable | Twisted-pair shielded cable, standard 5 m, extendable to 20 m in 5 m steps |
They are used for online verification and patrol measurement of liquid flow in water treatment, water plants, chemical, irrigation and industrial process water sites.
The manual describes four mounting methods: V method (standard, 25–400 mm pipes), N method, Z method (recommended 100–2000 mm for P6 and 100–5000 mm for P8), and W method for very small pipes under 50 mm.
Choose a pipe section that is always full of liquid, keep the pipe surface within the sensor temperature range, and avoid heavily corroded or scaled pipe sections; straight runs of ≥10D upstream and ≥5D downstream are indicated.
The package includes the ultrasonic flowmeter, sensors, sensor and output cables, lithium battery charger, mounting rail, fixing hooks, couplant, card reader, tape measure and a carrying case.