This product is an intelligent water pump controller with the following features: 1. Using high-precision impact-resistant liquid level sensor (transmitter), completely eliminating the stainless steel probe, float, photoelectric pressure gauge easy to damage, difficult to debug, unstable shortcomings, can real-time display the liquid level height, and can be adjusted in the panel or remote any working liquid level height. 2. Manual and automatic operation with phase error, three-phase unbalance, lack of phase, blocking, overcurrent, dry running, overvoltage, undervoltage protection; 3. By connecting with the remote control panel equipped with it, the voltage, current, liquid level height and other working conditions can be displayed remotely in real time, and all control functions can be realized.
This manual describes the L8 intelligent water pump controller with liquid level sensor type for protecting and controlling pumps such as deep well, submersible, pipeline booster, multistage and centrifugal pumps, and for automatic pressure control at construction sites or high-rise water supply. It uses a high-precision impact-resistant liquid level sensor (transmitter), displays liquid level height in real time, and allows working liquid level adjustment on the panel or remotely.
The manual covers liquid level control wiring, current setting and clearing, cumulative runtime query, fault query, common status and fault quick guide, typical control wiring diagrams, remote panel application, network expansion, and G-SC remote synchronous display controller application. Stated ratings include AC380V/50Hz supply, output power ranges from 0.75-4KW to 2.2-15KW, and IP54 protection. This manual is written in Chinese.
| Rated output power | 0.75-4KW, 5.5-7.5KW, 2.2-11KW, 2.2-15KW |
|---|---|
| Rated working voltage | AC380V/50Hz |
| Overcurrent action time | 5 seconds to 5 minutes |
| Phase loss action time | <2 seconds |
| Stall action time | <0.1 second |
| Undervoltage action time | <5 seconds |
| Overvoltage action time | <5 seconds |
| Undervoltage action voltage | 80% |
| Overvoltage action voltage | 115% |
| Dry-run protection action time | 6 seconds |
| Dry-run fault recovery time | 30 minutes |
| Overcurrent fault recovery time | 5 minutes |
| Recovery time for three-phase imbalance, undervoltage and overvoltage | 2 minutes |
| Compatible pressure sensor | 0-2.5Mpa |
| Liquid level sensor interface | PVC DN25 |
| Protection rating | IP54 |
| RS485 transmission distance | Within 1200 meters |
| Dimensions | 240 x 302 x 120 mm |
A new pump must undergo current setting. After maintenance or replacement of a pump, clear the previous current setting and perform current setting again.
Switch to manual mode, then press the stop key for more than 6 seconds until a beep sounds and "not set" is displayed.
Adjust the controller to manual stop state, press and hold the set/calibrate button, then press the stop key; the current and voltage displays show cumulative runtime. Press stop or wait 10 seconds to exit.
It indicates no water flow in the lower pool or well, or that pump air has not been fully discharged; it can also be used for deep well pump dry protection.