This product is a laser rangefinder with functions such as measuring distance, area, volume, height, Pythagorean theorem, addition and subtraction, and area addition.
This Spanish-language user manual describes a handheld laser distance meter with a measuring range of 0.05 m to 60 m and an accuracy of ±2.0 mm. It covers safety instructions for the Class II laser (<1 mW, 620–690 nm), battery installation, and the LCD icons and keyboard layout.
The manual explains single, continuous and max/min measurement, area, volume and indirect height measurement using the Pythagorean theorem, unit conversion between metric and imperial, reference point selection, backlight control, storage and recall of 30 groups of historical readings, automatic shut-off, and a troubleshooting table of error codes such as err101 and err154. This manual is written in Spanish.
| Measuring range | 0.05 m ~ 60 m |
|---|---|
| Measuring accuracy | ±2.0 mm (standard deviation) |
| Measurement units | m, ft, in; area in m², ft² |
| Laser type | 620 ~ 690 nm |
| Laser class | Class II, <1 mW |
| Laser spot size | 8 mm @ 10 m, 40 mm @ 50 m |
| Single measurement time | 0.25 ~ 4 s |
| Operating temperature | 0 ~ +40 °C |
| Storage temperature | -20 ~ +65 °C |
| Battery | 2 x 1.5 V AAA alkaline |
| Measurements per battery set | > 8000 |
| Historical data records | 30 groups |
| Automatic shut-off | Laser after 30 s, device after 180 s |
Within 10 m the accuracy is ±2.0 mm; beyond 10 m it is ±2.0 mm ± 0.1 × (D−10), where D is the measuring distance in meters.
The laser switches off automatically after 30 seconds and the device switches off after 3 minutes of inactivity.
err101 means the battery is too low; the solution is to change the batteries.
err154 means the target is out of range; measure the target within the measuring range.