M-D Pneumatics ® Rotary Positive Displacement Air Blower System Qube™ Models 400 800 1600 OPERATOR’S MANUAL
This operator's manual covers the M-D Pneumatics Qube™ rotary positive displacement air blower packages, models 400, 800 and 1600. It is written for operators and maintenance personnel and includes safety conventions, data plate explanations, installation steps, lubrication guidance, pressure relief valve use, accessories and maintenance recommendations.
The manual contains a specifications table with maximum RPM, maximum allowable working pressure and approximate weights for each model, plus sections on start-up, stopping, troubleshooting, recommended lubricants, parts lists and the blower product warranty. It references the Machinery Directive 2006/42/CE and EN 1012-1:1996, and notes that additional manuals ship with the Qube for the blower and electric motor.
| Model 400 max RPM | 4800 |
|---|---|
| Model 800 max RPM | 4000 |
| Model 1600 max RPM | 3200 |
| MAWP (all models) | 18 psi / 1.24 bar |
| Model 400 weight (without/with motor) | 824 / 1599 lbs (374 / 726 kg) |
| Model 800 weight (without/with motor) | 2550 / 3550 lbs (1157 / 1611 kg) |
| Model 1600 weight (without/with motor) | 3202 / 5202 lbs (1453 / 2360 kg) |
| Maximum ambient temperature | 104° F (40° C) |
While in storage, hand rotate the blower and motor every two to three months to prevent flat spots on the bearings that lead to premature failure.
If the unit has been stored for more than eighteen months, contact M-D Pneumatics before placing it into service.
The outlet can approach temperatures as high as 400° F (204° C), per the warning label placed at the process outlet.
No. The manual states the blower is not intended for explosive products or environments, or applications that include hazardous gases.