Logic Code Combi ESP1 is a combination boiler providing both central heating and instantaneous domestic hot water. Featuring full sequence automatic ignition and fan assisted combustion. Due to the high efficiency of the boiler
This user guide covers the Ideal Logic Code Combi ESP1 combination boiler, available in 26, 33 and 38 versions. The boiler provides both central heating and instantaneous domestic hot water, with full sequence automatic ignition and fan assisted combustion. As a high efficiency condensing appliance, it produces condensate that is drained through a plastic waste pipe at the base of the boiler.
The guide explains how to start the boiler, select winter, summer and off modes, adjust domestic hot water and central heating temperatures, top up system water pressure using the filling loop, and maintain the condensate drain. It also lists normal operation display codes and fault codes, and includes Benchmark service interval record information for UK installations.
| Electricity supply | 230 V ~ 50 Hz, 3A fuse |
|---|---|
| Max domestic hot water temperature | 65°C |
| Min domestic hot water temperature | 40°C |
| Max central heating radiator temperature | 80°C |
| Min central heating radiator temperature | 30°C |
| Frost protection activation | Below 5°C |
| Minimum operating pressure | 0.3 bar |
Connect the filling loop to the DHW inlet, turn the blue handles A and B to the horizontal position, and wait for the pressure gauge to reach 1 to 1.5 bar, then close the valves and disconnect the loop.
The status display shows 00 for standby with no heat demand, codes for central heating or domestic hot water being supplied, and FP when boiler frost protection is active.
Press the restart button (I) and the boiler will repeat its ignition sequence. If it still fails to start, consult a Gas Safe Registered Engineer.
Turn the central heating temperature knob to the economy position or lower, and reducing the room thermostat setting by 1°C can reduce gas consumption by up to 10%.