GEA Bock FK40 Series Vehicle Refrigeration Compressor Maintenance Manual

This document is a maintenance manual for refrigeration compressors manufactured by GEA Bock GmbH.


GEA Bock FK40 Series Vehicle Refrigeration Compressor Maintenance Manual - cover page
Brand
GEA Bock
Category
Car parts
Document type
Service Manual
Language
English
Pages
60
File format
PDF
File size
5 MB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
45A624DC85346DCF566EE282E13D4C96

About this manual

This GEA Bock maintenance manual covers the FK40 series vehicle refrigeration compressors. It provides safety information, product description, technical data, maintenance checks, and fault diagnosis for servicing personnel.

The repair sections describe disassembly and assembly of compressor components, including shut-off valves, oil filter, cylinder cover, valve plates, shaft seal, oil pump, baseplate, connecting rods, bearing flange, crankshaft, pistons, and roller bearings. Spare parts, repair kits, optional accessories, and an exploded drawing are listed.

What's inside

  • Introduction
  • Safety instructions
  • Product description
  • Technical data
  • Maintenance
  • Fault diagnosis / Remedying the malfunction
  • Installation of service kits
  • Compressor defects
  • Disassembly of compressor
  • Assembly of the compressor

Specifications

ApplicationVehicle compressor for mobile applications
Compressor designCompact 4-cylinder V design
ConstructionAluminium light-weight construction
Crankshaft supportCrankshaft supported in roller bearings on both sides
Oil pumpBidirectional lubricating oil pump with relief valve
Capacity rangeFour sizes as regards capacity

Frequently asked questions

What does this GEA Bock FK40 maintenance manual cover?

It is intended to make repair and maintenance of the FK40 easier and describes disassembly and assembly of compressor components.

Who may perform work on the refrigeration compressor?

Only qualified personnel are allowed to perform work on refrigeration compressors.

What must be done before commissioning the compressor?

The refrigerant system, including the compressor, must be evacuated carefully, then charged with refrigerant before starting.

Which FK40 design is listed for deep freezing?

The TK design is listed for deep freezing.