This document is the Haas Technical Publications Manual_Archive_Cover_Page Revision A, released on June 6, 2013.
This Haas Electrical Service Manual 96-0306 Rev G is a Spanish-language maintenance guide for Haas milling machines and lathes. It covers electrical safety, general electrical troubleshooting, electrical alarm identification, line voltage adjustments, electrical connections and fuse replacement.
The manual also documents front panel components, PCB replacement, control memory, discrete inputs and outputs, cable lists, PCB locations and wiring diagrams, cables, alarms and parameters. It is an archive publication intended for reference and illustrative purposes for Haas machine owners. This manual is written in Spanish.
| Intelligent amplifier current ratings | 30 A and 45 A |
|---|---|
| Pendant motor chain supply | 160 VDC |
| APC board supply | 115 V |
| Transformer voltage | 24 V |
Check the machine input voltage, the main switch position, the overvoltage fuses, the Power Off button wiring, the 24 V transformer connection and the I/O and power PCBs.
A damaged amplifier is indicated by a light at the lower part of the amplifier when power is on; replace the fuse in the amplifier.
Swap the motor cables and control cables between the suspect amplifier and the next one; if the problem moves to the other axis, the amplifier is faulty.
The Quad APC uses an additional PC card to control pallets 3 and 4.