RS Components ICM 135R Electrical Clamp Multimeter Instruction Manual

The document is about the instruction manual for the ICM 135R electrical clamp meter. The clamp meter has the following features: 1. Safety information 2. Operating instructions 3. Maintenance and care 4. Troubleshooting 5. Technical specifications


RS Components ICM 135R Electrical Clamp Multimeter Instruction Manual - cover page
Brand
RS Components
Category
multimeter
Document type
User Manual
Language
English
Pages
72
File format
PDF
File size
4.1 MB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
C2508A11ADF16BF98AAA064EFA490770

About this manual

This instruction manual covers the RS Components ICM 135R, an electrical clamp multimeter that measures AC current via its clamp jaw along with AC/DC voltage, resistance, continuity and frequency. The manual is printed in English, French, Italian, German and Spanish.

It explains safety precautions, power on/off and auto power off, the data hold, min/max hold and peak hold functions, the backlight, battery replacement, cleaning and maintenance, followed by the meter's specifications. The ICM 135R has a 4000-count display, is rated IEC 61010-1 600V CAT III and accepts conductors up to 34 mm in diameter.

What's inside

  • Safety Information
  • Power On / Off
  • Data Hold
  • Min / Max Hold
  • Peak Hold
  • Battery Replacement
  • Specifications
  • Maintenance
  • Cleaning
  • Limited Warranty

Specifications

Display4000 counts, 3 3/4 digit LCD
Measuring rate1.5 times / sec
Auto power offApproximately 30 minutes after power on
Power requirement9V battery type 6LR61 (IEC) Alkaline
Battery life200 hours (alkaline 9V)
Overvoltage categoryIEC 61010-1 600V CAT III
Operating temperature0°C to 50°C with humidity limits depending on range
Storage temperature-20 to +60°C, 0 to 80% RH (batteries not fitted)
Operating altitude2000 m (6562 ft)
Conductor size34 mm diameter
EMCEN 61326-1
CalibrationOne year calibration cycle

Frequently asked questions

What battery does the ICM 135R use and how long does it last?

It uses a 9V alkaline battery, type 6LR61 (IEC), with a typical battery life of 200 hours.

Does the clamp multimeter turn off automatically?

Yes, it powers off approximately 30 minutes after power on; pressing any button except Hold or rotating the rotary switch resets this function.

What size conductors fit in the clamp jaw?

The clamp accepts conductors up to 34 mm in diameter.

Can I repair the meter myself?

No, the clamp-multimeter contains no user-serviceable parts; contact RS Components for repair, servicing or calibration.