The SolaX Power Network Technology(Zhejiang) Co., Ltd. X1 Series User Manual 0.6kW - 3.6kW provides an overview of the features and specifications of the X1 series of photovoltaic inverters.
The SolaX X1 Series User Manual describes the assembly, installation, commissioning, maintenance and failure of the X1 Series PV inverters. These inverters convert DC current from a PV generator into AC current and feed it into the public grid; the manual is intended for qualified electricians.
The document covers models from 0.6 kW to 3.6 kW and explains the S, D, N and L model designations. It includes safety instructions, technical data, installation steps, LCD operation, troubleshooting, routine maintenance and decommissioning.
| S suffix meaning | single or one MPPT string |
|---|---|
| D suffix meaning | with DC switch |
| N suffix meaning | without DC switch |
| L suffix meaning | with LCD display |
| RCD trip threshold (electrocution protection) | 30 mA |
| RCD trip threshold (slow rising current) | 300 mA |
| PV generator capacitance limit | approx. 700 nF |
| Recommended external RCD type | type A |
It converts DC current from the PV generator into AC current and feeds it into the public grid.
S means single or one MPPT string.
The default value is 30 mA.
Wait 5 minutes before opening the upper lid or DC lid.