This manual is for the ATD Tools ATD-5519 auto-ranging digital multimeter. It covers safety precautions, features, terminals, push-button functions, measurement ranges, and electrical specifications.

It also explains DC and AC voltage and current, resistance, capacitance, frequency, and duty cycle measurements, along with auto/manual ranging, data hold, and maintenance including battery and fuse replacement.

What's inside

  • Features and specifications
  • Safety precautions
  • Measurement range
  • Terminals and push buttons
  • DC and AC voltage measurement
  • DC and AC current measurement
  • Resistance measurement
  • Capacitance measurement
  • Frequency and duty cycle measurement
  • Maintenance, battery and fuse replacement

Specifications

Measurement range modeAuto range / Manual range
Polarity indicationAutomatic positive; minus sign for negative
Overrange indicationOL
Data holdData hold function

Frequently asked questions

What should be done before measuring resistance in a circuit?

Turn off power to the circuit and discharge all capacitors before taking the measurement.

What limit applies to in-circuit current measurements?

Never attempt an in-circuit current measurement where the open-circuit potential to earth is greater than 600V.

How can you confirm a capacitor is discharged before measuring capacitance?

Use the DC voltage function to confirm that the capacitor is discharged before measuring capacitance.

What does the meter indicate when a measurement is over range?

The meter shows an OL indicator for overrange.