Carrier Transicold 69UG15 PowerLINE Series 55 Diesel Generator Set Operations and Service Manual

This manual provides instructions on the operation and maintenance of diesel generator sets.


Carrier Transicold 69UG15 PowerLINE Series 55 Diesel Generator Set Operations and Service Manual - cover page
Brand
Carrier TRANSICOLD
Category
Generator
Document type
Service Manual
Language
English
Pages
59
File format
PDF
File size
8.4 MB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
5353C0980808AD03BB9CB4F7D8BA0245

About this manual

The Carrier Transicold model 69UG15 Series 55 is a diesel-driven generator set that provides a constant electrical power supply for all-electric refrigeration units. It is an under-mounted unit secured to the frame rails of a container trailer chassis and consists of a Kubota four-cylinder diesel engine directly connected to a 15 kW alternating current generator in a structural steel frame.

This Operations and Service Manual, document T-375 Rev A, covers safety, description, operation, troubleshooting, service and preventative maintenance, schematics, and the EU Declaration of Conformity. It applies to units PID UG5500 to 5599 and states that the Series 55 model is EU Stage V compliant.

What's inside

  • Safety Summary
  • Description
  • Operation
  • Troubleshooting
  • Service and Preventative Maintenance
  • Schematics
  • EU Declaration of Conformity
  • Unit Specifications

Specifications

Generator output15 KW, 18.75 KVA, 0.8 pf
Output voltage400-500 VAC at 60 Hz; 360-460 VAC at 50 Hz
Speed1800 RPM at 60 Hz; 1500 RPM at 50 Hz
Generator weight121 kg
Generator part number54-00738-20
EngineVertical, in-line, four-cylinder diesel manufactured by Kubota
Engine displacement2.22 liters (2216 cm3)
Compression ratio22.0 to 1
Bore / stroke83 mm / 102.4 mm
Engine dry weight199 kg approximate

Frequently asked questions

What engine is used in the 69UG15 generator set?

It uses a vertical, in-line, four-cylinder diesel engine manufactured by Kubota.

What is the generator output of the 69UG15?

The generator provides 15 KW and 18.75 KVA at 0.8 pf.

What does the CE mark on the Series 55 model indicate?

It verifies that the 18.5 kW engine complies with Europe’s Stage V non-road mobile machinery emissions standard.

What precautions are required before working on the generator set?

All circuit breakers and start-stop switches must be turned off, and the negative battery terminal must be disconnected.