IMP PUMPS PlusLine xx/40 and xx/60 Series High Efficiency Circulating Pump Installation and Operating Manual

This document describes the features and specifications of the PlusLine xx/40 and xx/60 series of high-efficiency circulating pumps.


IMP PUMPS PlusLine xx/40 and xx/60 Series High Efficiency Circulating Pump Installation and Operating Manual - cover page
Brand
IMP PUMPS
Category
Other products
Document type
User Manual
Language
German
Pages
7
File format
PDF
File size
461 KB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
8CE446C708AD52061BB44807A05576B7

About this manual

IMP PUMPS PlusLine xx/40 and xx/60 are high-efficiency circulating pumps for liquids in central heating, ventilation, solar and air-conditioning systems. They are driven by a permanent magnet motor and continuously measure pressure and flow, automatically adjusting delivery. The permitted medium is pure water or a suitable mixture of pure water and glycol; aggressive or explosive additives are not allowed, and the pump must not be used for flammable or explosive media.

The manual covers installation with the motor shaft horizontal, electrical connection to 230 V, 50 Hz, pump setting with proportional-pressure and constant-strength curves, technical data, fault diagnosis and warranty conditions. It also lists EU conformity information, including EEI values of 0.20 for PlusLine xx/40 and 0.22 for PlusLine xx/60. This manual is written in German.

What's inside

  • Compliance with EU standards
  • General
  • Installation of the pump
  • Electrical connection
  • Pump setting
  • Technical data
  • Fault overview
  • Warranty conditions

Specifications

Ambient temperature0°C to 40°C
Medium temperature5°C to 110°C
Maximum system pressure10 bar
Supply voltage230 V, 50 Hz
Protection classIP44
Insulation classF
Energy Efficiency Index (PlusLine xx/40)0.20
Energy Efficiency Index (PlusLine xx/60)0.22
PlusLine -/40 speed II powerRegulated 7–25 W; unregulated 17 W
PlusLine -/40 speed III powerRegulated 10–25 W; unregulated 25 W

Frequently asked questions

What media can the PlusLine pumps handle?

Pure water or a suitable mixture of pure water and glycol; aggressive or explosive additives are not permitted, and the pump must not be used for flammable or explosive media.

How is constant pump output selected?

A press on the setting button longer than 5 seconds selects constant pump output.

Does the pump need a vent screw?

No, the pumps vent themselves through the drilled ceramic shaft.

What is the warranty period?

The manufacturer provides a 36-month warranty from the date of sale.