ASD934 is a wireless charging intelligent test equipment integrating fast charging source and electronic load functions. It is mainly used for testing wireless charging transmitters, with a maximum support of 15W, compatible with QI, Samsung, Apple and EPP standards, and can test multiple functions of two products with one key.
This Chinese user manual describes the ASD934 wireless charging intelligent test equipment from Asundar (昂盛达). The equipment consists of a tester and a 10.1-inch Android touch screen, combines a fast-charge power supply and an electronic load, and is used for testing wireless charging transmitters and receivers. It supports up to 15 W and is compatible with QI, Samsung, Apple and EPP standards, and can test two products at once through dual test channels.
The manual covers inspection and installation, quick start (self-check, front panel, rear panel and touch screen), technical specifications, function features such as research mode and automatic mode, basic operation, device interfaces and warranty terms. Parameter setting, data processing and report export are all done on the touch screen host, and files can be imported or exported through USB storage. This manual is written in Chinese.
| Transmitter supply voltage range | 0–20 V |
|---|---|
| Transmitter current range | 0–5 A |
| QC supply selectable voltages | 5, 9, 12, 20 V |
| PD supply selectable voltages | 5, 6, 9, 12, 15, 19, 20 V |
| Resolution | Voltage 1 mV; current 1 mA |
| Supply ripple | 30 mVp-p |
| Receiver load range | Voltage 0–20 V; current 0–2 A |
| Screen | 10.1 inch, 1024 × 768 |
| Storage capacity | 5 GB |
| Operating system | Android 4.4.2 |
| Cooling | Air cooling, 3 fans (37.2 CFM, 38.4 dB(A)) |
| Operating temperature | 0 to 40 °C |
| Dimensions | Tester 483 mmD × 462 mmW × 110 mmH; host 260 mmD × 145 mmW × 222 mmH |
| Weight | 5.75 kg |
Up to 15 W; the equipment supports 5 W, 7.5 W, 10 W and 15 W power tests.
The equipment is compatible with QI, Samsung, Apple and EPP standards.
Two products can be tested in one run through the dual test channels.
198–242 Vac at 47–63 Hz, connected to a properly grounded socket through the three-core power cord.