The 2 gallon water boiler user guide introduces the features and specifications of the product.
The Wilbur Curtis 2 Gallon Water Boiler User's Guide covers the WB-2A10 domestic model and WB-2A30 export model. It begins with key features, specifications and system requirements, then gives important safeguards and installation instructions, including leveling, connecting the water supply and first-time power-up.
The document also includes cleaning instructions, a rough-in drawing, illustrated parts lists, an electrical schematic, troubleshooting guides and a product warranty. The specifications table lists electrical requirements, dimensions, water supply requirements, phase, voltage, amps and watts for each model.
| Domestic model electrical requirements | 1 PH, 120 V, 13.3 A, 1 x 1600 W |
|---|---|
| Export model electrical requirements | 1 PH, 220 V, 9.5 A, 1 x 2000 W |
| Dimensions and weight | 23.85 in high, 8.00 in wide, 14.86 in deep; 26.0 lbs; 5.3 cu ft |
| Water supply pressure | 20 - 90 psi |
| Minimum flow rate | 1.0 gpm |
| Water tank capacity | 2.0 gallons |
The water supply pressure must be between 20 and 90 psi, with a minimum flow rate of 1.0 gpm.
It typically takes 20 to 30 minutes to reach the factory set operating temperature, depending on incoming water temperature and electrical specifications.