BBC Bircher EsGate 2 Safety Monitor User Manual

The EsGate 2 is a safety monitor for monitoring industrial door pressure sensors (for safety edges according to EN ISO 13856-2). It meets the requirements of protection class PLd,Cat.2 according to EN ISO 13849-1.


BBC Bircher EsGate 2 Safety Monitor User Manual - cover page
Brand
BBC Bircher
Category
Automation control Equipment
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
613 KB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
12E9D241895DFA2F79F1B1975C6A79D5

About this manual

The EsGate 2 is a safety monitor from BBC Bircher for sensors with an 8.2 kΩ terminating resistor, used to monitor pressure sensors on industrial doors (safety edges according to EN ISO 13856-2). It meets the PLd, Cat. 2 requirement of EN ISO 13849-1, and the device may be installed in a simple, industrial or even controlled electromagnetic environment. It runs on safety extra-low voltage (SELV) with safe electrical isolation according to EN 61558.

This Chinese-language operating manual covers safety instructions, general application, functions, terminal assignment and wiring, applying the supply voltage, function tests, the read-only diagnostics menu, configuration (edit) mode, service mode, fault display and technical data. The unit has two sensor inputs, two safety outputs, one status output, an LED, an LCD display and Mode and Data buttons, and is configured from the front panel during initial commissioning. This manual is written in Chinese.

What's inside

  • Safety instructions
  • General application
  • Functions
  • Terminal assignment and wiring
  • Applying the supply voltage
  • Function test
  • Diagnostics menu (read-only)
  • Configuration mode (edit mode)
  • Service mode
  • Fault display

Specifications

Supply voltage (DC)24 V DC ±15 %
Supply voltage (AC)24 V AC ±15 %, 50/60 Hz
Power consumptionMax. 3 W
Sensor inputsFor sensors with 8.2 kΩ termination
Safety outputsSolid-state relays, 24 V AC/DC, max. 50 mA
Response time (on activation)< 20 ms
Start-up time< 500 ms
HousingGray/red polyamide
Dimensions22.5 x 94 x 88 mm (W x H x D)
MountingDirect DIN rail mounting
Degree of protectionIP20 (EN 60529)
Operating temperature–20 °C to +60 °C
Storage temperature–40 °C to +70 °C

Frequently asked questions

What sensors can the EsGate 2 monitor?

It is designed for sensors with an 8.2 kΩ terminating resistor, used on industrial door pressure sensors (safety edges according to EN ISO 13856-2).

How do I enter the diagnostics menu?

Press the Mode and Data buttons simultaneously for 2 seconds; the orange status LED then flashes.

What happens when a sensor is triggered?

The total resistance of the sensor system drops to zero, the corresponding safety output opens, the orange LED lights up and the display shows “P”.

What does fault code E001 mean?

E001 indicates defective wiring on sensor 1, and the remedy is to check sensor 1.

Download PDF (613 KB)