The EsGate 2 is a safety monitor for monitoring industrial door pressure sensors (for safety edges according to EN ISO 13856-2). It meets the requirements of protection class PLd,Cat.2 according to EN ISO 13849-1.
The EsGate 2 is a safety monitor from BBC Bircher for sensors with an 8.2 kΩ terminating resistor, used to monitor pressure sensors on industrial doors (safety edges according to EN ISO 13856-2). It meets the PLd, Cat. 2 requirement of EN ISO 13849-1, and the device may be installed in a simple, industrial or even controlled electromagnetic environment. It runs on safety extra-low voltage (SELV) with safe electrical isolation according to EN 61558.
This Chinese-language operating manual covers safety instructions, general application, functions, terminal assignment and wiring, applying the supply voltage, function tests, the read-only diagnostics menu, configuration (edit) mode, service mode, fault display and technical data. The unit has two sensor inputs, two safety outputs, one status output, an LED, an LCD display and Mode and Data buttons, and is configured from the front panel during initial commissioning. This manual is written in Chinese.
| Supply voltage (DC) | 24 V DC ±15 % |
|---|---|
| Supply voltage (AC) | 24 V AC ±15 %, 50/60 Hz |
| Power consumption | Max. 3 W |
| Sensor inputs | For sensors with 8.2 kΩ termination |
| Safety outputs | Solid-state relays, 24 V AC/DC, max. 50 mA |
| Response time (on activation) | < 20 ms |
| Start-up time | < 500 ms |
| Housing | Gray/red polyamide |
| Dimensions | 22.5 x 94 x 88 mm (W x H x D) |
| Mounting | Direct DIN rail mounting |
| Degree of protection | IP20 (EN 60529) |
| Operating temperature | –20 °C to +60 °C |
| Storage temperature | –40 °C to +70 °C |
It is designed for sensors with an 8.2 kΩ terminating resistor, used on industrial door pressure sensors (safety edges according to EN ISO 13856-2).
Press the Mode and Data buttons simultaneously for 2 seconds; the orange status LED then flashes.
The total resistance of the sensor system drops to zero, the corresponding safety output opens, the orange LED lights up and the display shows “P”.
E001 indicates defective wiring on sensor 1, and the remedy is to check sensor 1.