Physis AxN Size2 Configurable Motion Control Platform Installation Manual

This manual describes the installation procedure for the AxN series of configurable motion control platforms.


Physis AxN Size2 Configurable Motion Control Platform Installation Manual - cover page
Brand
Physis
Category
Automation control Equipment
Document type
Installation Guide
Language
Chinese
Pages
40
File format
PDF
File size
6.8 MB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
E5BFD960455A1FA3007E06E0536E36FC

About this manual

This is the Chinese-language installation manual (Version V1.9) for the Physis AxN Series Configurable Motion Control Platform, written for the AxN Size2 model AxN 015.030.4. It starts with mechanical installation: operating precautions, installation environment conditions, outer dimensions, the required vertical mounting direction and the minimum clearances to the cabinet, other devices and the exhaust/intake areas.

The rest of the document covers electrical connection. Chapter 2 describes the AC power input (power requirements, cable fabrication and installation, braking resistor wiring and motor power output), chapter 3 covers the control circuit (auxiliary supply port AUX_Power, Safe Torque Off (STO) and system status port R1), and chapter 4 describes the communication ports (encoder port E1 for sin/cos, EnDat, incremental, resolver and Hiperface encoders, serial port I1, main CAN port C1, EtherCAT IN/OUT and user-defined ports U1–U4). An appendix lists orderable motor power and encoder cables. This manual is written in Chinese.

What's inside

  • Operation precautions
  • Installation environment
  • Outer dimensions
  • Mounting direction
  • Mounting clearances
  • AC power input
  • Braking resistor
  • Motor power connection
  • Auxiliary power supply and STO
  • Communication ports

Specifications

Input voltage150–500 Vac
Input frequency50/60 Hz
Operating ambient temperature0 °C to 40 °C; up to 60 °C with derating
Altitude0–1000 m; above 1000 m, power (current) derated 1% per 100 m
Vibration tolerance2–9 Hz: amplitude below 0.3 mm; 9–200 Hz: acceleration below 1 m/s2
Mounting directionVertical, installed in a cabinet with airflow upward
AxN 015.030.4 AC input cable15 A rms, 4.17 mm2, AWG 11
Maximum AC power cable length0.5 m
Clearance A100 mm to the top of the cabinet

Frequently asked questions

What input power does the AxN Size2 model AxN 015.030.4 require?

It takes a three-phase AC supply of 150–500 Vac at 50/60 Hz.

How long may the AC power cable between the filter and the drive be?

The cable length must not exceed 0.5 m.

How must the AxN Size2 drive be mounted?

It must be mounted vertically inside the electrical cabinet so that the internal airflow direction is upward.

What minimum clearance is needed above the drive?

A clearance of 100 mm to the top of the cabinet is required.