ST-330B Automatic Analysis Cable Tester adopts time domain analysis method to test the faults of various voltage levels of power cables, communication coaxial cables and telephone cables.
This is the Chinese user manual for the ST-330B 自动分析电缆测试仪 (automatic analysis cable tester) from Wuhan Shixin (武汉世鑫). The instrument uses time-domain analysis to locate low-resistance, short-circuit, open-circuit, high-resistance leakage and high-resistance flashover faults in power cables, coaxial communication cables, local telephone cables, control cables, mining cables and submarine cables of various voltage levels.
The manual covers safety requirements, an instrument overview, technical descriptions including the measurement principle (S=VT/2 based on transmission line and radar ranging theory), operating instructions, fault testing procedures using the low-voltage pulse method and high-voltage flashover method, usage precautions, and after-sales service information. The tester consists of an industrial touchscreen all-in-one computer, a USB data acquisition unit, a high-energy polymer battery and charger, and offers automatic waveform analysis that displays the fault distance on screen. This manual is written in Chinese.
| Distance measurement range | 4 m – 40 km |
|---|---|
| Distance measurement accuracy | Error ≤ 1 m below 1 km; relative error ≤ 0.5% above 1 km |
| Pulse amplitude | Not less than 250 V at 50 Ω |
| Pulse width | 0.2 μs, 2 μs, 4 μs |
| Sampling frequency | 48 MHz |
| System measurement error | 10 cm with dual-probe cable fault pinpointing instrument |
| Power supply | AC 220 V ±10%, 50 Hz ±5%, or built-in rechargeable polymer battery |
| Battery operation time | About 6 hours continuous when fully charged |
| Working temperature | -10 °C to 50 °C |
| Preset propagation velocities | Oil-soaked paper 160 m/μs; XLPE 172 m/μs; PVC 184 m/μs; mining rubber cable 100 m/μs |
The instrument provides the low-voltage pulse method (低压脉冲法) and the high-voltage flashover method (高压闪络法), plus methods such as impulse high-voltage current sampling and DC high-voltage flashover.
When fully charged, the instrument can work continuously for about 6 hours on the built-in polymer rechargeable battery.
It can test copper and aluminum core power cables below 35 kV, coaxial communication cables and telephone cables for open-circuit, short-circuit, high-resistance flashover and high-resistance leakage faults.
After adjusting the waveform with the amplitude potentiometer, stop sampling, enter waveform analysis, and tap the automatic analysis option in the right-hand menu; the fault distance is then shown on the screen.