YBK3 series coal mine explosion-proof three-phase asynchronous motor is suitable for fixed equipment in coal mine working face with methane or dust as general power equipment.


Huali YBK3 Series Coal Mine Explosion-Proof Three-Phase Asynchronous Motor Use and Maintenance Manual - cover page
Brand
Huali
Category
AC Motors
Document type
User Manual
Language
Chinese
Pages
15
File format
PDF
File size
600 KB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
9736FBDE483582693BB8B586A8FE19B0

About this manual

YBK3 series coal mine explosion-proof three-phase asynchronous motors (frame sizes H80 to H355) are built to GB/T 3836.1-2021 and GB/T 3836.2-2021 with explosion-proof marking ExdbIMb for fixed equipment in coal mine faces containing methane or dust. The manual gives specifications, structure, explosion-proof points, installation and wiring, operation, maintenance, transport and storage, and safety warnings.

Rated voltages include 380 V, 660 V, 1140 V, 380/660 V and 660/1140 V at 50 Hz, with Class F insulation and a continuous S1 duty rating. It also covers bearing lubrication, disassembly and assembly, drying of damp windings, and required checks before use. This manual is written in Chinese.

What's inside

  • Applicable scope and purpose
  • Product model and explosion-proof marking
  • Main specifications and installation structure
  • Working environment conditions
  • Product structure features
  • Explosion-proof points
  • Operation instructions
  • Maintenance and repair
  • Transportation and storage
  • Safety warnings

Specifications

Frame sizeH80 to H355
Explosion-proof markingExdbIMb
Execution standardsQ/1082SHL105-2021 and MT451-2011
Energy efficiency levelLevel 3
Rated voltage380 V, 660 V, 1140 V, 380/660 V, 660/1140 V
Rated frequency50 Hz
Insulation classClass F
Temperature rise assessment85 K
Minimum ambient air temperature-15 °C
Maximum altitude1000 m
Maximum relative humidity95% at 25 °C
Duty typeContinuous (S1)
Bearing temperature limit90 °C
Drying temperature limit155 °C
Maximum surface temperature130 °C
Hydrostatic test1.0 MPa for 10 s

Frequently asked questions

What is the explosion-proof marking of the YBK3 motor?

The explosion-proof marking is ExdbIMb.

What are the rated voltages?

Rated voltages are 380 V, 660 V, 1140 V, 380/660 V and 660/1140 V.

Can the terminal box cover be opened while the motor is energized?

No, opening the terminal box cover while energized is strictly prohibited.