This document is the operation manual of CIF-A series AC power supply, which introduces the electrical specifications, panel說明, backplane說明, operating procedures, accessories and equipment, input and output wiring specifications, simple troubleshooting and other contents of the series of products.
This is the operation manual (revision 1.0, file CIF-A-C1, PN 800-01027, dated 2002/05/08) for the Chyng Hong CIF-A Series AC power supply. The series covers models from the CIF2000 (2 kVA) up to the CIF3030 (30 kVA), with single-phase two-wire output, ±0.5% voltage stability, selectable 50 Hz / 60 Hz / 400 Hz / 47–63 Hz variable output frequency, ≤2% waveform distortion and forced-air cooling. Over load, short circuit and over temperature protection are provided, and readings are shown on digital voltage, current, frequency and watt meters.
The manual describes the front panel controls and status indicators (POWER, VOLTAGE, RESET, RANGE 150V/300V, OUTPUT, frequency selector and adjustment, limit setting), the rear panel including the auxiliary output socket rated 20A(Rms), and the 9U, 14U and 19U chassis layouts. It also covers the operating procedure, accessories, input and output wiring specifications, a troubleshooting table with causes and remedies, and an appendix with wire gauge, current and resistance tables. This manual is written in Chinese.
| Input voltage | AC V ±10%, 50/60 Hz |
|---|---|
| Frequency stability | FIX ±0.01 Hz; VAR ±0.1 Hz |
| Output capacity models | CIF2000 (2 kVA), CIF3000 (3 kVA), CIF5000 (5 kVA), CIF7500 (7.5 kVA), CIF1030 (10 kVA), CIF1530 (15 kVA), CIF2030 (20 kVA), CIF3030 (30 kVA) |
| Protection | Over load, short circuit, over temperature |
| Auxiliary output socket | Maximum 20A (Rms) |
The RANGE switch selects between 150V and 300V output voltage levels.
The auxiliary output socket can carry a maximum of 20A (Rms).
It provides over load, short circuit and over temperature protection.
The selector offers 50 Hz, 60 Hz, 47–63 Hz variable, or 400 Hz.