Quadra-Fire 3100 Millennium 31M-ACC-C Wood Appliance Owner's Manual

The document describes the operation and maintenance of the 3100 series fireplace.


Quadra-Fire 3100 Millennium 31M-ACC-C Wood Appliance Owner's Manual - cover page
Brand
Quadra-Fire
Category
Heater
Document type
User Manual
Language
English
Pages
32
File format
PDF
File size
4.8 MB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
A69BAF809EB8A783FE4445835751887A

About this manual

The Quadra-Fire 3100 Millennium is a wood appliance with Automatic Combustion Control (ACC), identified as model 31M-ACC-C. This Owner’s Manual Operation & Care is intended to stay with the party responsible for use and operation and covers operation, care, and safety information.

The document includes a sample serial number/safety label, warnings about hot surfaces and over-firing, floor protection requirements, vent specifications, and minimum clearances to combustible materials for single-wall and double-wall pipe, mobile home, and alcove installations. It states that installation and service should be performed by qualified personnel.

What's inside

  • Sample of Serial Number / Safety Label
  • Welcome to the Quadra-Fire Family
  • Floor Protection
  • Vent Specifications
  • Minimum Clearances to Combustible Materials
  • Mobile Home Installation
  • Alcove Installation
  • Installation: Full Vertical or Horizontal with Minimum 2 ft Vertical Off Stove Top
  • Installation: 90° Elbow Off Top of Stove Through Backwall

Specifications

Model number31M-ACC-C
Fuel typeSolid wood only
Vent diameter6 in (152 mm)
Optional blower electrical rating115 VAC, 1.2 Amps, 60 Hz
Floor protector minimum thickness3/8 in (9.5 mm) non-combustible material or equivalent
Particulate emission rate1.9 G/HR using crib wood
Glass replacement5 mm ceramic
Mobile home outside air kitOAK-ACC
Optional blower part numberBK-ACC

Frequently asked questions

What fuel should I use in the Quadra-Fire 3100 Millennium?

It is for use with solid wood fuel only; other fuels may over-fire and generate poisonous gases.

What is the electrical rating for the optional blower?

The optional blower is rated at 115 VAC, 1.2 Amps, 60 Hz.

What vent pipe diameter is specified?

The manual specifies a six inch (152 mm) diameter connector pipe.

Where should the appliance not be installed in a mobile home?

For mobile homes, do not install the appliance in a sleeping room.

Download PDF (4.8 MB)