Saiduo SOTO-AE/Code300T Air Sterilizer User Manual

The Seto air sterilizer uses electrostatic adsorption technology to effectively remove particulate matter, bacteria and viruses from the air.


Saiduo SOTO-AE/Code300T Air Sterilizer User Manual - cover page
Brand
Saiduo
Category
Air Cleaners Purifiers
Document type
User Manual
Language
Chinese
Pages
20
File format
PDF
File size
31.3 MB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
996EE4474A3E50F184F1C33036FBC4BD

About this manual

This is the Chinese user manual (产品使用说明书) for the Saiduo brand SOTO-AE/Code300T air sterilizer, also listed under the general name SOTO-YD1. It opens with warranty terms, safety precautions and a description of how the machine works: room air is drawn in by a fan and treated by a pre-filter, an electrostatic dust collector, an activated carbon filter, a UV lamp with photocatalyst, and a negative ion generator.

The manual then lists the main components, technical parameters and features, and explains installation, key operations on the display panel, remote control preparation, maintenance, troubleshooting and the electrical connection diagram. A filter cleaning record sheet for the pre-filter and the electrostatic collector closes the document. This manual is written in Chinese.

What's inside

  • Warranty Statement
  • Safety Precautions
  • Main Structure and Working Principle
  • Features and Technical Parameters
  • Main Component Names
  • Installation
  • Operation
  • Maintenance
  • Troubleshooting
  • Electrical Connection Diagram

Specifications

Product nameSaiduo brand SOTO-AE/Code300T air sterilizer
General nameSOTO-YD1
Rated power supply220 V, 50 Hz
Rated power60 W
Negative ion concentration3x10^6 ions/cm³
Fuse rating250 V, 2 A
Dimensions82.8 cm x 47.8 cm x 23 cm
UV wavelength254 nm
Operating environment0-40 °C, relative humidity < 75%
Remote control batteryCR2025
Remote control rangeabout 6 m

Frequently asked questions

What power supply does the SOTO-AE/Code300T air sterilizer require?

It requires a rated supply of 220 V / 50 Hz, and the installation site must be properly grounded.

How long does it take to disinfect a 60 m³ room?

With the machine running at the highest fan speed with UV and negative ions on, 1 hour of operation meets the disinfection requirement for 60 m³ of indoor air.

How far away does the remote control work?

The remote works up to about 6 m, and may not respond if an obstacle stands between the remote and the signal receiver.

How do I reset the timer after replacing the activated carbon filter or UV lamp?

While the machine is on, press and hold the power key for 3 seconds until a beep sounds to reset the timer.

Where may the air sterilizer not be used?

It must not be used in environments with flammable, explosive or corrosive gases, since this can cause fire or explosion.