The VTR4 strobe light is a high performance, multi-function strobe light that is suitable for a wide range of applications. It features:
This manual is for the Gardasoft VTR4 strobe light and applies to all variants in the VTR4 range unless otherwise stated. It covers safety guidance, mounting, electrical connections, power supply and trigger input details, and configuration commands.
The manual also documents part-number conventions, error and event codes, restrictions, and product specifications such as heat dissipation, trigger input levels, and pulse timing.
| Wavelength options | 850 nm, 940 nm, white |
|---|---|
| Beam angle options | 12 or 28 degrees (white), 14 or 28 degrees (IR) |
| Communications options | ETH, RS232 |
| Maximum heat dissipation | 80 W |
| Case temperature | up to 65 C |
| Internal circuit voltage | exceeds 46.7 V; should not exceed 60 V |
| Power supply current | at least 4.0 A |
| Maximum power supply cable length | 3 m |
| Opto-isolator isolation | up to 50 V |
| Trigger input on voltage | 5 V to 24 V |
| Trigger input off voltage | 0 V to 2 V |
| Trigger input current | about 3 mA |
| Temperature rise without heatsinking | 0.45 C per W |
| Maximum internal temperature | below 70 C |
| Minimum light pulse delay | approximately 2 us |
| Minimum retrigger delay | approximately 5 us |
| Fault detection pulse width | does not operate below approximately 70 us |
| Minimum trigger output delay | approximately 2 us |
| Thermal cutout | around 65 C to 70 C |
The convention is VTR4-www-aa-ccc, where www is wavelength, aa is beam angle, and ccc is communications.
The external power supply needs to be able to supply at least 4.0 A.
A voltage of 5 V to 24 V across the trigger inputs sets the input to logic 1 (on).
Err 33 indicates that the VTR4 is too hot.