Qixing Huachuang FVH05-G6 FVH10-G6 FVH20-G6 High Pressure Filter Manual

FVH type filter is suitable for common gas filtration, with high corrosion resistance and good sealing.


Qixing Huachuang FVH05-G6 FVH10-G6 FVH20-G6 High Pressure Filter Manual - cover page
Brand
Qixing Huachuang
Category
Other products
Document type
User Manual
Language
Chinese
Pages
3
File format
PDF
File size
109 KB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
908F9A730FDA2D3001485A91F4EC9F3A

About this manual

This manual covers the Qixing Huachuang FVH05-G6, FVH10-G6 and FVH20-G6 high pressure filters for ordinary gas filtration. It lists filtration accuracy by model, flow rate, maximum working pressure, operating temperature, materials, connection type and overall dimensions.

It also explains the working principle and gives installation instructions, including gas flow direction, double-ferrule fitting tightening and precautions such as regular cleaning or replacement of the filter core. This manual is written in Chinese.

What's inside

  • Purpose
  • Technical specifications
  • Working principle
  • Installation instructions
  • Dimensions
  • Precautions

Specifications

Filtration accuracyFVH05-G6: 5-10 μm; FVH10-G6: 10-20 μm; FVH20-G6: 20-30 μm
Gas flow rateMaximum 62.5 L/min at 0.05 MPa pressure drop for 20-30 μm filtration; higher precision reduces flow
Maximum working pressure10 MPa
Working environment temperature0-65 °C
Metal parts material00Cr17Ni14Mo2 (316L)
Seal materialFluororubber
Inlet/outlet connectionΦ6 standard double ferrule (Swagelok) fitting
Overall dimensions95 × ø27 mm (length × diameter)

Frequently asked questions

What is the maximum working pressure of these filters?

The maximum working pressure is 10 MPa.

What is the working temperature range?

The working environment temperature range is 0-65 °C.

What type of fittings are used for the inlet and outlet?

The inlet and outlet use Φ6 standard double ferrule (Swagelok) fittings.

What maintenance is recommended for the filter?

The filter core should be cleaned or replaced regularly.