This document is about the use and care manual for gas water heaters.
The manual covers GHE80SS, GHE80SU, GHE100SS and GHE100SU Category IV fan-assisted commercial high efficiency water heaters. It states that installation and maintenance should be performed by a qualified, licensed service professional, and includes installation, venting, operating, maintenance and troubleshooting instructions.
It lists gas and electrical supply requirements, clearances, ignition and temperature control information, alarm and alert codes, parts lists and wiring diagrams. The water temperature is adjustable up to 185°F (85°C), and the water heater temperature is set to 120°F (49°C) at the factory.
| Models covered | GHE80SS, GHE80SU, GHE100SS, GHE100SU |
|---|---|
| Combustion category | Category IV fan-assisted combustion |
| Minimum inlet gas pressure, natural gas | 3.5 in. WC |
| Minimum inlet gas pressure, LP gas | 11.0 in. WC |
| Maximum inlet gas pressure, natural gas | 10.5 in. WC |
| Maximum inlet gas pressure, LP gas | 13.0 in. WC |
| Electrical requirement | 120 Vac, 60 Hz, 7 amp minimum |
| Maximum water temperature setting | 185°F (85°C) |
| Factory water temperature setting | 120°F (49°C) |
| Clearance to combustibles | 0 in. at sides and back; 6 in. at top |
| Recommended service clearance | 24 in. at front and top |
It covers GHE80SS, GHE80SU, GHE100SS and GHE100SU.
The water heater temperature is adjustable up to 185°F (85°C).
It requires 120 Vac, 60 Hz and a minimum of 7 amps.
The minimum inlet gas pressure for natural gas is 3.5 in. WC.