This document is the operator's manual for the M18™ Transfer Pump. The pump is for use with clear water only. It is not designated to handle salt water, brine, laundry discharge, or any other application which may contain caustic chemicals and/or foreign material. This pump is not suitable for use with aquatic life.
This is the operator's manual for the Milwaukee M18 TP transfer pump, a battery-powered pump that runs on 18 V DC M18 battery packs and M18 chargers. It sets out the general pump safety warnings, work area and personal safety rules, battery tool use and care, service notes, symbology, specifications and a functional description of the pump's parts.
The manual explains operation: attaching the inlet and outlet hoses, placing the inlet hose below the water surface, securing the discharge hose, inserting and removing the battery pack, and switching the pump on and off. It states the pump is for clear water only, with a maximum water temperature of 60°C (140°F), a maximum lift of 5.5 m (18') and a maximum head height of 23 m (75').
| Cat. No. | M18 TP |
|---|---|
| Volts | 18 DC |
| Battery Type | M18™ |
| Charger Type | M18™ |
| Max Flow Rate | 30.3 L/min |
| Max Lift | 5.5 m (18') |
| Max Head Height | 23 m (75') |
| Max Water Temperature | 60°C (140°F) |
| Max Air Temperature | 40°C (104°F) |
| Fittings | 13 mm (1/2") NPT male to 19 mm (3/4") BSPT Male |
The maximum flow rate is listed as 30.3 L/min.
The pump has been evaluated for use with clear water only and is not for potable water or other potable liquids.
The manual says not to run the pump for more than 1 hour continuously.
The pump should not be allowed to run dry for more than 10 seconds; turn it off quickly when the job is complete.