Milwaukee M18 TP Transfer Pump Operator's Manual

This document is the operator's manual for the M18™ Transfer Pump. The pump is for use with clear water only. It is not designated to handle salt water, brine, laundry discharge, or any other application which may contain caustic chemicals and/or foreign material. This pump is not suitable for use with aquatic life.


Milwaukee M18 TP Transfer Pump Operator's Manual - cover page
Brand
Milwaukee
Category
Other
Document type
User Manual
Language
English
Pages
6
File format
PDF
File size
1.8 MB
Published
10 November, 2023
Updated
10 November, 2023
Model
M18 TP
MD5 checksum
AE6A4F62C723FAB8004416C7C14329D2

About this manual

This is the operator's manual for the Milwaukee M18 TP transfer pump, a battery-powered pump that runs on 18 V DC M18 battery packs and M18 chargers. It sets out the general pump safety warnings, work area and personal safety rules, battery tool use and care, service notes, symbology, specifications and a functional description of the pump's parts.

The manual explains operation: attaching the inlet and outlet hoses, placing the inlet hose below the water surface, securing the discharge hose, inserting and removing the battery pack, and switching the pump on and off. It states the pump is for clear water only, with a maximum water temperature of 60°C (140°F), a maximum lift of 5.5 m (18') and a maximum head height of 23 m (75').

What's inside

  • General Pump Safety Warnings
  • Pump Use and Care
  • Work Area Safety
  • Personal Safety
  • Battery Tool Use and Care
  • Service
  • Symbology
  • Specifications
  • Functional Description
  • Assembly

Specifications

Cat. No.M18 TP
Volts18 DC
Battery TypeM18™
Charger TypeM18™
Max Flow Rate30.3 L/min
Max Lift5.5 m (18')
Max Head Height23 m (75')
Max Water Temperature60°C (140°F)
Max Air Temperature40°C (104°F)
Fittings13 mm (1/2") NPT male to 19 mm (3/4") BSPT Male

Frequently asked questions

What is the maximum flow rate of the M18 TP transfer pump?

The maximum flow rate is listed as 30.3 L/min.

What type of water can this pump be used with?

The pump has been evaluated for use with clear water only and is not for potable water or other potable liquids.

How long may the pump run continuously?

The manual says not to run the pump for more than 1 hour continuously.

How long can the pump run dry?

The pump should not be allowed to run dry for more than 10 seconds; turn it off quickly when the job is complete.