This document is about the user manual of Bertazzoni PRO series gas range.
This manual is the installation, use and care manual for Bertazzoni PRO30 4 GAS freestanding gas ranges, covering models PRO30 4 GAS X, AR, BI, NE, RO and VI. It provides safety information, product specifications, installation requirements, and operating instructions for surface and oven cooking.
It also includes gas conversion steps, maintenance and cleaning guidance, and warranty and service information.
| Auxiliary burner power | 3730 BTU/h natural gas; 3750 BTU/h LP gas |
|---|---|
| Semi-rapid burner power | 6000 BTU/h natural gas; 6300 BTU/h LP gas |
| Rapid burner power | 10400 BTU/h natural gas; 11400 BTU/h LP gas |
| Dual burner inner power | 2730 BTU/h natural gas; 2900 BTU/h LP gas |
| Dual burner outer power | 15000 BTU/h natural gas; 16400 BTU/h LP gas |
| Oven burner power | 14500 BTU/h natural gas; 14500 BTU/h LP gas |
| Broiler burner power | 12000 BTU/h natural gas; 12000 BTU/h LP gas |
| Maximum inlet gas supply pressure | 20 in. w.c. (5 kPa) |
| Minimum gas supply pressure | At least 1 in. w.c. (249 Pa) above specified manifold pressure |
| Operating gas pressure (natural gas) | 4 in. w.c. (1.00 kPa) |
| Operating gas pressure (LP gas) | 11 in. w.c. (2.75 kPa) |
Do not light any appliance, do not touch any electrical switch, do not use any phone in the building, and immediately call the gas supplier from a neighbor's phone; if the supplier cannot be reached, call the fire department.
It is shipped from the factory for use with natural gas, and a conversion procedure is provided for LP gas.
All Bertazzoni products carry a 2 year parts and labor warranty.
It must be installed by an authorized professional in accordance with the manufacturer's instructions and applicable codes.