This solenoid is suitable for gas, steam and mist mixtures. It fully complies with GB3836.1 - 2010 and GB3836.9 - 2014 standards.
These operating instructions from Eugen Seitz AG cover the solenoid coil types 14A80, 14C80 and 14F52, which are used to drive solenoid valves made by Eugen Seitz AG. The document lists the explosion protection markings and the standards the coils comply with, and it states that the coils are approved for installation on category 2, equipment group II equipment and are therefore suitable for zone 1 and zone 2 areas with potentially explosive gas, vapor and mist mixtures.
The manual describes the required operating conditions, electromagnetic compatibility, general safety warnings and the work of authorized personnel. It explains how to fit the O-ring and coil onto the valve's guide tube for 14A80/14C80 and 14F52, how to connect the integrated cable, and how to disassemble the coil. A technical data section gives rated voltage tolerance, duty cycle, humidity and dust protection, current type, rated power and fuse values, and the document closes by stating that the coils must not be repaired and must be discarded or returned to the manufacturer. The text is presented in Chinese, German and Spanish. This manual is written in Chinese.
| Rated voltage tolerance | -10 % / +10 % of the voltage on the nameplate |
|---|---|
| Duty cycle | 100 % (continuous operation) |
| Humidity | max. 80 % humidity (no dew or condensation) |
| Protection degree | IP 65/67 according to IEC 60 529 |
| Rated power | 14A80: 10 W; 14C80: 7 W / 12 VA; 14F52: 12 W / 12 VA |
| Current type | 14A80: DC, max. 20 % ripple; 14C80: AC, 50…60 Hz; 14F52: AC, 50…60 Hz or DC, max. 45 % ripple |
| Explosion protection marking, 14A80 and 14C80 (gas, vapor, mist) | Ex mb IIC T4 Gb |
| Explosion protection marking, 14F52 (gas, vapor, mist) | Ex e mb II C T4 Gb |
They are used to drive solenoid valves produced by Eugen Seitz AG.
They are approved for category 2, equipment group II equipment and are therefore suitable for zone 1 and zone 2 areas with potentially explosive gas, vapor and mist mixtures.
First the O-ring is placed in the valve's metal guide tube, then the coil is fitted onto the guide tube.
No. To ensure explosion protection the coils must not be repaired or modified; they are to be discarded or returned to the manufacturer.