Leadvision 48" x 24" LED Edge Light Panel Installation Guide

This document is an installation guide for a 48" x 24" LED edge light panel. The panel has an input voltage of 120-347 volts, an input frequency of 60 hertz, and an input wattage of 30-35-45 watts.


Leadvision 48" x 24" LED Edge Light Panel Installation Guide - cover page
Brand
Leadvision
Category
lighting LED
Document type
Installation Guide
Language
English
Pages
2
File format
PDF
File size
593 KB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
81B8FD9DB2B73A538C388BC584BDD432

About this manual

This two-page bilingual (English/French) installation guide covers the Leadvision 48" x 24" LED Edge Light Panel, a fixture that lays into a T-grid ceiling. It lists input voltage of 120 - 347 V, 60 Hz input frequency, 30 - 35 - 45 W input watts and an operating temperature range of -20 C to +45 C, and states the panel is suitable for IC installations and for wet/damp locations.

The first page gives numbered safety instructions: wiring must follow the national electrical code, connections must be made by a qualified electrician, power must be off at the circuit breaker panel, wires must not be pinched, and damaged fixtures must not be installed. The second page shows the installation sequence in numbered steps: bend out the four mounting tabs, remove the wiring compartment cover and make the wiring connections, set the selector switches to the desired CCT and wattage (factory default 3500K and Hi), lay the fixture into the T-grid, bend the tabs over the T-grid and attach the cable to the ceiling structure, then restore power. A limited lifetime warranty of over 50 000 hours is stated.

What's inside

  • Safety instructions
  • Bend out (4) mounting tabs
  • Wiring information
  • Set selector switches for CCT and wattage
  • Lay fixture into T-grid
  • Bend tabs over T-grid and attach cable
  • Restore power
  • Warranty

Specifications

Input Voltage120 - 347 V
Input Frequency60 Hz
Input Watts30 - 35 - 45 W
Operating Temperature-20 C to +45 C
Location SuitabilitySuitable for IC installations; can be used in wet/damp location
Default Setting3500K (35K) and (Hi) highest voltage
WarrantyLimited lifetime warranty; exchange or refund if the product does not last over 50 000 hours

Frequently asked questions

What input voltage does the LED Edge Light Panel require?

The panel accepts an input voltage of 120 - 347 V at 60 Hz.

Can the panel be used in wet or damp locations?

Yes. The guide states it is suitable for IC installations and can be used in wet/damp location.

How do I set the CCT and wattage?

Set the selector switches to the desired CCT and wattage; the factory default is 3500K (35K) and (Hi) highest voltage.

What warranty does Leadvision give on this LED panel?

Leadvision LED lighting has a limited lifetime warranty; if the product does not last over 50 000 hours, Leadvision will exchange or refund it for the price purchased.