This product is a weighing sensor with linear compensation, humidity compensation, external zero debugging, external span debugging, input overload protection and output short circuit protection functions.
This manual covers the ATO load cell transmitter, an aluminum alloy unit with standard 0-5V, 0-10V, 4-20mA, and 0-20mA output signals, linear and humidity compensation, external zero and span debugging, input overload protection, and output short-circuit protection. It includes the specification table, dimensional drawing, and wiring diagram.
The manual also provides calibration examples for output current and output voltage signals, with step-by-step debugging procedures and calculation formulas for 4-20mA, 0-20mA, 4-12-20mA, 0+10V, and 0+5V outputs.
| Model | ATO-LCTR-DY510 |
|---|---|
| Accuracy | +0.05%FS |
| Input signal | 0.5-4mV |
| Excitation voltage for load cell | DC5V |
| Output signal (DC) | 0-+5V/0-+10V/4-20mA/0-20mA |
| Power supply | DC 18-30V |
| Sampling frequency | 2100KHZ |
| Housing material | Aluminum alloy |
It requires a DC 18-30V power supply.
It supports 0-5V, 0-10V, 4-20mA, and 0-20mA output signals.
It provides DC5V excitation voltage for the load cell.
It equals object weight divided by load cell capacity, multiplied by the net current output, plus the zero current.