IXARO IXARO-NET-POE-Transmitter Manual

The IXARO-NET transmitter is equipped with an Ethernet interface to be directly connected to a local network. The power is also supplied over the Ethernet cable (Power Over Ethernet = POE).


IXARO IXARO-NET-POE-Transmitter Manual - cover page
Brand
IXARO
Category
Communications equipment
Document type
User Manual
Language
English
Pages
13
File format
PDF
File size
1.8 MB
Published
09 November, 2023
Updated
09 November, 2023
MD5 checksum
2F8F245AC796CD19E2611142C474E8EA

About this manual

The IXARO-NET-POE-Transmitter is a network-connected radio transmitter powered over Ethernet (POE). The manual describes its two power levels, IXARO-NET 10L and IXARO-NET P500, and their frequency, range, and modulation differences.

It covers wall mounting, antenna and cable requirements, RJ45 or NE8MC Ethernet connection, DIP-switch device numbering, diagnostic LEDs, Ethernet interface configuration with ezTCP Manager, and a specifications table.

What's inside

  • Description
  • Hardware Installation
  • Setting of the device number
  • Location and meaning of the diagnostic LED's
  • Configuration of the Ethernet Interface
  • Mounting of the Neutrik-plug NE8MC
  • Specifications
  • Declaration of Conformity

Specifications

Size177 × 81 × 57 mm (L × W × H)
MaterialDie cast aluminium, coated grey
ProtectionIP54
Temperature range–10° up to +40° C
Frequency433,5 MHz (IXARO-NET 10L); 446,1625 MHz (IXARO-NET P500)
Output power10 mW (IXARO-NET 10L); 500 mW (IXARO-NET P500)
Modulation+/– 4 Khz FM (IXARO-NET 10L); +/– 2 Khz FM (IXARO-NET P500)
Transmit ProtocolPOCSAG
Baudrate512
Supply voltage9 up to 32 Volt
Transmit range (light buildings)600 m (IXARO-NET 10L); 2 km (IXARO-NET P500)
Maximum range (free field)2 km (IXARO-NET 10L); 5 km (IXARO-NET P500)

Frequently asked questions

How is the IXARO-NET-POE-Transmitter powered?

Power is supplied over the Ethernet cable (POE); the maximum permitted voltage is 32 Volt and the supplied 18 Volt power supply is recommended.

How many transmitters can be used in one system?

A maximum of 9 transmitters is supported.

What does the Status-LED indicate?

It lights when the transmitter is in use by the software and blinks when there is no connection.

How is the device number set?

It is set with the internal DIP-switch in binary code, where the rightmost switch is the least significant bit and ON represents a logical one.