OSRAM SYLVANIA 3500 Hot Air Tool Operating Instructions

The OSRAM 1/24/01 SYLVANIA Process Heat Hot Air Tool 3500 is a compact, efficient heater with a stainless steel housing and positive hose-barb air connection for heating air or inert gases to 1400°F (760°C). A built-in “K” thermocouple allows for closed-loop control of temperature to ±1°F of set point. If operated correctly, the heater will operate continuously for 5000 hours or longer.


OSRAM SYLVANIA 3500 Hot Air Tool Operating Instructions - cover page
Brand
OSRAM SYLVANIA
Category
Heater
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
777 KB
Published
09 November, 2023
Updated
09 November, 2023
MD5 checksum
E5314C4E1D37DC2DE7E30E9C355EFE62

About this manual

The OSRAM SYLVANIA Process Heat 3500 hot air tool is a compact heater with a stainless steel housing and a hose-barb air connection. It heats air or inert gases to 1400°F (760°C). A built-in type K thermocouple supports closed-loop control to ±1°F of set point, and the manual states the heater can run continuously for 5000 hours or longer when operated correctly.

The instructions list model numbers 068462, 068463, 068464, 070878 and 071383, and give maximum wattage, voltage and current for the first three. They also cover maximum inlet pressure and temperature, safety and precaution notes, installation and start-up steps, performance curves for temperature and voltage limits, and the OSRAM SYLVANIA warranty.

What's inside

  • Description
  • Specifications
  • Safety
  • Precautions
  • Installation
  • Start-up
  • Performance Curves
  • Warranty

Specifications

Maximum inlet pressure60 PSI (4 bar)
Maximum inlet air temperature120°F (50°C)
Maximum exit air temperature1400°F (760°C)
Model 0684621500 W maximum, 120 V, 13 A
Model 0684632000 W maximum, 240 V, 9 A
Model 0684643500 W maximum, 240 V, 15 A
Temperature control accuracy±1°F of set point with closed-loop control
Housing and air connectionStainless steel housing with hose-barb air connection
Air tubing¼ in. ID high pressure tubing

Frequently asked questions

What is the maximum exit air temperature of the 3500 hot air tool?

The maximum exit air temperature is 1400°F (760°C).

Can I apply power before starting the airflow?

No. Always have sufficient airflow through the heater before applying power, otherwise the element will overheat and burn out.

Where should the thermocouple be placed?

It should be located within one inch from the heater exit.

What type of power controller should be used?

Use phase angle fired power controllers; on-off controllers may shorten heater life or burn out the element.