The TB-68 is a 68Pin shielded terminal box with temperature conversion module and matching 5500 series data acquisition module functions.
This is the V1.1.0 user manual (February 22, 2022) for the JYTEK TB-68, a 68-pin shielded terminal block for PXIe/PCIe data acquisition modules. It begins with a quick-start section explaining the abbreviations AI, AO, DI, DO and PFI, then lists the electrical specifications and the J1–J4 pin definitions of the SCSI-II connector.
The operating guide explains how to enable the built-in 1-channel temperature conversion module, which outputs a signal voltage on pin 68, and gives the quadratic relation between that voltage and temperature. It also provides the pin mapping for connecting the TB-68 to 5510/5511 and 5515/5516 boards, followed by company information about JYTEK and a legal notice. This manual is written in Chinese.
| Connector | 68-pin SCSI-II female |
|---|---|
| Supported wire gauge | 30-12 AWG / 0.05-3.31 mm² |
| Rated current (single pin) | 0.2 A |
| Rated voltage (any pin to pin) | 250 V |
| Temperature conversion module | 1 channel |
| Temperature conversion module operating temperature range | -10 °C to 60 °C |
The compatible module list gives the PXIe/PCIe 5510, 5511, 5515 and 5516, which are marked as recommended; the 6301 and 6302 are listed without a recommendation mark.
Enable the temperature conversion module; it then outputs a signal voltage on pin 68 of the SCSI-II connector, which an appropriate DAQ module measures. Temperature follows T = aV² + bV + c, with a = −7.857923E−6, b = −1.777501E−1 and c = 2.043937E+2 for ambient temperatures between −10 °C and 110 °C.
No. The manual states that the target voltage cannot be measured at the terminal with instruments such as a multimeter; a compatible DAQ module must be used.
It is recommended that the PCIe/PXIe-5500 series board sample rate not exceed 400 Samples/sec.