This manual applies to the following versions of SYON 2000: Power Supply Module: DS3012 Firmware Version: 1.2 Application Version: 1.0


STOP CASA SEGURA SYON 2000 DS3012 Access Control Installation Manual - cover page
Brand
STOP CASA SEGURA
Category
Attendance
Document type
Installation Guide
Language
Spanish
Pages
17
File format
PDF
File size
1.5 MB
Published
08 November, 2023
Updated
08 November, 2023
MD5 checksum
BDD7882793FE6A843BF4B8DA0B883441

About this manual

This installation manual covers the STOP CASA SEGURA SYON 2000, described in the text as a stand-alone access control unit based on Bluetooth and RFID media. The document states that it applies to SYON 2000 units with power supply module DS3012, firmware version 1.2 and application version 1.0, and it explains that information for SYON 100 and SYON 200 models is presented together in the same manual.

The manual starts with safety, warranty and documentation notes, then covers mechanical installation (explosive-area warnings, mounting accessories, wall mounting and DIN-T35 rail mounting), electrical installation (power supply, earthing, overvoltage protection, terminal list, relay outputs, door-open inputs, RFID readers and the optional 2.4 GHz antenna), plus troubleshooting and specifications. The unit is built around an electronic board in an ABS housing with flame retardant to UL94-V0 and IP-54 protection index. This manual is written in Spanish.

What's inside

  • Lea esto primero (documentation, safety, warranty, symbols, abbreviations)
  • Introducción
  • Instalación mecánica
  • Instalación en zonas explosivas
  • Accesorios de montaje
  • Montaje en pared o superficie lisa
  • Montaje en carril
  • Instalación eléctrica
  • Suministro eléctrico, puesta a tierra y protección de sobretensión
  • Listado de bornas y conexiones

Specifications

Supply voltage9 to 12 VDC (no polarity requirement)
Maximum current consumed without loads12 VDC, 150 mA, 1.8 W
Recommended mains supply110 V to 230 V AC input, 12 V DC output, minimum 0.3 A
Relay output ratingPotential-free, max. 1 A at 110 V AC or 30 V DC
Door-open input voltageApproximately 12 VDC
Operating temperature-40 to +70 °C
Protection indexIP-54
Housing materialABS plastic with flame retardant to UL94-V0
RFID reader frequency125 kHz (Unique models)
Antenna2.4 GHz, optional

Frequently asked questions

What is the SYON 2000?

The manual describes it as a stand-alone access control unit based on Bluetooth and RFID media, built around an electronic board in an ABS housing.

What supply voltage does the SYON 2000 accept?

Power is connected at terminals 9-10 and accepts direct voltage between 9 and 12 VDC. No polarity needs to be observed because the system is protected against reverse voltage.

How are the relay outputs of the SYON 2000 connected?

The relay outputs are connected to terminals 1-2, 3-4, 5-6 and 7-8 and are potential-free relays rated at a maximum of 1 A at 110 V AC or 30 V DC.

Can the unit be mounted on a DIN rail?

Yes, using the DIN-T35 rail clip accessory, which provides the fixing needed to place the housing on a 35 mm symmetrical T-type rail.