Memmert VO Series Vacuum Drying Oven Operating Instructions

This document provides the operating instructions for the VO series vacuum drying oven.


Memmert VO Series Vacuum Drying Oven Operating Instructions - cover page
Brand
Memmert
Category
Ovens
Document type
User Manual
Language
Chinese
Pages
28
File format
PDF
File size
1 MB
Published
08 November, 2023
Updated
08 November, 2023
MD5 checksum
4119D943A0E290B9C49E942E3EADCA6E

About this manual

This document is the Chinese operating instructions for the Memmert VO series vacuum drying oven (真空烘箱), distributed in China by 美墨尔特(上海)贸易有限公司. It describes the required installation environment, the oven and vacuum pump structure, and preparation steps such as connecting the hose, pump module, power cables and inert gas supply.

The instructions explain operation of the touch control panel, including temperature setting (RT-200℃), vacuum setting, countdown timer (up to 99 days 23 hours), mode selection, USB data export, a quick air-inlet function for opening the door, heating shelf status display, and cleaning and maintenance of the chamber, plastic parts and glass surfaces. This manual is written in Chinese.

What's inside

  • 使用环境 (Operating environment)
  • 箱体结构 (Unit structure)
  • 产品操作 (Operation)
  • 前期准备 (Preparation)
  • 温度设置 (Temperature setting)
  • 真空度设置 (Vacuum setting)
  • 倒计时设置 (Countdown setting)
  • 模式选择 (Mode selection)
  • U盘数据导出 (USB data export)
  • 仪器保养 (Maintenance)

Specifications

Ambient temperature5-40℃
Ambient humiditymax. 80%, non-condensing
Power supply230V (±10%), 50/60Hz
Temperature setting rangeRT-200℃
Countdown rangemax. 99 days 23 hours
Inert gas inlet pressuremax. 1.5 bar
Clearance above unitat least 20 cm

Frequently asked questions

How do I open the oven door when the chamber pressure is below atmospheric pressure?

Rotate the knob in the vacuum setting area until "OpenDoor" appears, then press the confirm key so external gas enters and the door can be opened.

What cleaning agents should be used on the working chamber and surfaces?

Use a dedicated stainless steel cleaner regularly; chlorine-containing cleaners must not be used.

What happens after the countdown finishes?

After reaching the set temperature and vacuum, the countdown starts; when it ends the oven goes into standby, with an audible signal if the sound function is on.

Which mode should pharmaceutical industry customers use?

The mode should always be set to manual mode, in which temperature and vacuum values can be set manually and maintained.

Download PDF (1 MB)