The GTR-168 is a cost-effective, full-featured diesel engine generator controller with UL, CUL and CE certification. It uses a key switch to control the generator, providing manual, shutdown and automatic modes, and is easy to operate without special training. Shutdown protection functions include: emergency stop, overspeed, high water temperature, low oil pressure and multiple cranking failures. It also provides low battery voltage warning operation and DC power indication. It uses European terminals, and the wiring is firm and easy to install and replace. There is a group of 10拨动开关 on the back of the controller, which can be set according to system requirements to achieve inventory reduction and programmable control. The built-in 5 power relays can withstand 5 amps of DC current, eliminating the need for external power relays, saving installation and wiring costs. The GTR168 is your best choice in terms of function, protection and ease of operation.
The GTR-168 is a diesel engine generator controller from 宏晋仪控科技 (Monicon) that carries UL, CUL and CE certification. It is operated with a key switch offering Auto, Off and Manual modes, and provides shutdown protection for emergency stop, overspeed, high water temperature, low oil pressure and repeated cranking failure, along with low battery warning and DC power indication. The rear carries a 10-pin DIP switch for system settings and five built-in relays rated for 5 A DC.
The manual describes the front panel lamps and operating switch, the rear board terminal assignments, the DIP switch functions, dimensions and specifications, and gives an example controller wiring diagram plus UL installation notes. This manual is written in Chinese.
| DC Power Supply | 8–36 VDC |
|---|---|
| Power Consumption | Max. 5 W |
| Frequency Measurement | 0–80 Hz, input voltage range 5–300 V AC |
| Relay Outputs | Start, fuel valve, preheat, alarm and stop relays: 5 A each |
| Operating Temperature | -40 °C to 70 °C |
| Dimensions (W x H x D) | 72 mm × 72 mm × 58 mm |
| Panel Cutout (W x H) | 68 mm × 68 mm |
| Weight | 160 g (0.35 lb) |
| Cranking Attempts | 3 times |
| Overspeed Protection | 2 s, 55/66 Hz |
It operates from 8 to 36 VDC and draws a maximum of 5 W.
Set DIP switch Pin3 to ON for 50 Hz; OFF selects 60 Hz.
Auto (ATS) standby with external ATS contact detection, Off for manual stop and alarm reset, and Manual for local starting of a stopped engine.
Three cranking attempts, with protection functions paused for 5 seconds after a successful start.