This document describes the installation and operating instructions for the Webtrol pump.
This manual covers installation and operation of Webtrol FC/TC Series stainless steel centrifugal pumps. It includes safety rules, performance specifications, pump inspection and handling, exploded views, pre-installation, installation, electrical connections, startup, and lubrication.
TC models have suction sizes from 1-1/4 to 1-1/2 inch NPT and a 1 inch NPT discharge; FC models have suction sizes from 2 to 2-1/2 inch ANSI and discharge sizes from 1-1/4 to 2 inch ANSI. Both series use 304 stainless steel casing and impeller, stainless shaft, and carbon/ceramic Viton mechanical seal.
| TC suction size (TC70) | 1-1/4 inch NPT |
|---|---|
| TC suction size (TC120) | 1-1/4 inch NPT |
| TC suction size (TC200) | 1-1/2 inch NPT |
| TC discharge size | 1 inch NPT (all TC models) |
| TC HP range at 1750 RPM | 1/3 to 1-1/2 HP |
| TC HP range at 3450 RPM | 3/4 to 3 HP |
| TC capacity | 5.5 to 100 GPM |
| TC head | 23 to 144 feet |
| TC liquid | Clean water |
| TC liquid temperature | 212°F (250°F optional) |
| TC working pressure | 125 PSI |
| TC casing material | 304 stainless steel |
| TC impeller material | 304 stainless steel |
| TC shaft material | Stainless steel |
| TC mechanical seal | Carbon/ceramic Viton |
| TC motor frame | Nema 56J frame, 60 Hz |
| TC motor overload protection | Built-in overload protection (single phase models) |
| FC suction size (FC32) | 2 inch ANSI |
| FC suction size (FC40) | 2-1/2 inch ANSI |
| FC suction size (FC50) | 2-1/2 inch ANSI |
| FC discharge size (FC32) | 1-1/4 inch ANSI |
| FC discharge size (FC40) | 1-1/2 inch ANSI |
| FC discharge size (FC50) | 2 inch ANSI |
| FC HP range at 1750 RPM | 1 to 2 HP |
| FC HP range at 3450 RPM | 3 to 30 HP |
| FC capacity | 13 to 600 GPM |
| FC head | 33 to 285 feet |
| FC liquid temperature | 212°F (250°F optional) |
| FC working pressure | 230 PSI |
| FC casing material | 304 stainless steel |
| FC impeller material | 304 stainless steel |
| FC shaft material | Stainless steel |
| FC mechanical seal | Carbon/ceramic Viton |
| FC motor frame | Nema JM frame, 60 Hz |
No. Running the pump dry will severely damage the pump and mechanical seal.
The supply voltage must be within + 10% of nameplate voltage.
Do not operate the pump with water temperature above 212° F.
The FC Series discharge can only be used in the normal position.