Lanstar LX-61 Series Low Energy Ranch Controller User Manual

The LX-61 series is a new energy controller launched by Shenzhen Lanxing Technology Co., Ltd. It is small in size, simple in appearance and easy to install. There is a pulse generator inside the controller, which generates a high-voltage pulse through the control pulse generator and outputs it periodically. With the front-end conductive cable, the high-voltage pulse is transmitted to a closed area surrounded by the front-end wire, which can effectively block the movement of animals inside and outside the area.


Lanstar LX-61 Series Low Energy Ranch Controller User Manual - cover page
Brand
Lanstar
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
15
File format
PDF
File size
1.1 MB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
76DB2FDB45BC9087174B66CD298FCF15

About this manual

The Lanstar LX-61 Series is a low-energy ranch controller made by Shenzhen Lanstar Technology. It contains a pulse generator that periodically produces a high-voltage pulse; when connected to front-end conductive cables around a closed area, the pulse is used to deter animals from entering or leaving. The manual lists pasture, woodland, grassland, farm, fruit and vegetable garden use, and describes LED indications for normal output, no output, and abnormal output.

The manual covers product appearance and dimensions, technical parameters, installation and use, grounding instructions, precautions, repair service, electrical parameter description, and accessories. It explains powering by adapter, battery, or solar panel with lead-acid battery, gives grounding and mounting requirements, and provides cable-layout examples for different animals. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Product Appearance and Dimensions
  • Technical Parameters
  • Installation and Use
  • Grounding Instructions
  • Precautions
  • Repair Service
  • Product Electrical Parameter Description
  • Accessories

Specifications

Input voltage12 VDC
Output voltage12 kV ±500 V
Operating current95 mA–350 mA
Pulse period1.2 s
Adapter input voltage range110 VAC–240 VAC
Load distance3500 m–30,000 m
Operating temperature-25 °C to +50 °C
Relative humidity90%
ProtectionWaterproof and dustproof design

Frequently asked questions

What areas is the LX-61 Series suitable for?

The manual lists pasture, woodland, grassland, farm, and fruit and vegetable garden use.

How high should the main unit be mounted above the ground?

The main unit should be at least 1.5 m above the ground to prevent animals and children from touching it.

What is the maximum high-voltage grounding resistance?

The high-voltage grounding resistance should be no more than 10 ohms.

What power sources can the controller use?

It can use a 12 V lead-acid battery or a power adapter.

Download PDF (1.1 MB)