Meishi GCRT-1012 Electric Chain Hoist Installation and Operation Manual

GCRT-1012 Electric Chain Hoist Installation and Operation Manual


Meishi GCRT-1012 Electric Chain Hoist Installation and Operation Manual - cover page
Brand
Meishi
Category
Other
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
3.7 MB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
FFCEA30D8E71BCD77FD9649D542B08C6

About this manual

The Meishi GCRT-1012 is an electric chain rigging point (电动环链式数控吊点) made by Guangzhou Meishi Innovation Technology Co., Ltd. It is installed with a hook mounting and is used to hang various kinds of stage equipment from a ceiling; the supplied decorative ring covers the ceiling cutout.

The manual gives installation requirements and precautions, a product structure diagram with the standard and optional accessories, wiring instructions for dry contact and RS-485 control with pin assignments and hex control codes, the connection method for using several units together, a troubleshooting table, and a specification table. This manual is written in Chinese.

What's inside

  • Troubleshooting (故障排除)
  • Precautions (注意事项)
  • Wiring Instructions (接线说明)
  • RS-485 Protocol
  • Product Structure Diagram (产品结构图)
  • Standard and Optional Accessories
  • Wiring Multiple Devices
  • Specifications (规格参数)
  • Installation Instructions (安装说明)

Specifications

Product modelGCRT-1012
DimensionsW287 x D162 x H403.7 mm
Mounting methodHook mounting
Ceiling cutoutφ175 mm (depending on site conditions)
Maximum load100 Kg
Maximum travel12000 mm
Input voltage220V 50Hz
Rated power45 W
Control methodRS-485 control, dry contact
RS-485 port settings2400 bps, 8 data bits, no parity, 1 stop bit
Product standardJB/T5317-2016

Frequently asked questions

What is the maximum load of the GCRT-1012?

The maximum load is 100 Kg.

What control methods does the GCRT-1012 support?

It is controlled by RS-485 or by dry contact.

What is the maximum travel of the hoist?

The maximum travel is 12000 mm.

What are the RS-485 port settings?

The port is set to a bit rate of 2400, 8 data bits, no parity and 1 stop bit.

Download PDF (3.7 MB)

More Meishi Manuals