This instruction manual covers the Cedar KTM-4B-25 and DI-4B-25 digital torque checkers and carries the document code OSH-Q08. It begins with 18 numbered safety warnings about the workplace, charging the built-in Ni-Cd battery and handling the instrument, then describes the front panel controls, including the power switch, mode selector, direction switch, zero switch, charging socket, LCD, impact counter and timer setting switches.

A specifications section lists the measuring ranges, accuracy, measurement modes, RS-232C output, power supply and dimensions. The manual then explains how to connect the input and output test connectors, how to choose between the PP, TR and PD measurement modes, how to set the automatic clear time, how data is transmitted, how to charge the battery, and what the one-year warranty and calibration service cover; a troubleshooting table closes the document. This manual is written in Chinese.

What's inside

  • 安全警告 (Safety Warnings)
  • 外观 (Appearance and Part Names)
  • 规格 (Specifications)
  • 准备与测量方法 (Preparation and Measurement Method)
  • 测量方式 (Measurement Procedure)
  • 自动归零设定 (Automatic Clear Setting)
  • 数据传输 (Data Transmission)
  • 充电 (Charging)
  • 服务保证 (Warranty)
  • 调修服务 (Calibration and Repair Service)

Specifications

ModelKTM-4B-25; DI-4B-25
Measuring range (N·m)0.50 to 25.00
Measuring range (kgf·cm)5.0 to 250.0
Measuring range (lbf·in)5.0 to 220.0
Accuracy+/- 0.5% for 500 to 5000 digit readings; +/- 3% for 30 to 499 digit readings
Display4-digit liquid crystal display
Measurement modesPP peak, TR track, PD peak down
Data outputRS232C serial interface, 9600 Baud (optional)
Power supply6 VDC (Ni-Cd rechargeable battery, 1.2V x 5 cells)
Auto power offSwitches off automatically after 5 minutes of non-use
Charging timeLess than 8 hours
Continuous working timeApproximately 13 hours
Battery lifeMore than 300 recharges (varies with working conditions)
Dedicated chargerInput AC120V or AC230V 50/60Hz; output DC7.25V (120mA)
Dimensions150(W) x 115(D) x 40(H)
WeightApproximately 2.1 kg

Frequently asked questions

What measurement modes does the torque checker offer?

There are three modes: PP (peak), which shows the maximum torque value; TR (track), which shows the real-time torque value; and PD (peak down), which holds the value at the moment the load drops.

What is the measuring range of the KTM-4B-25 / DI-4B-25?

The range is 0.50 to 25.00 N·m, which corresponds to 5.0 to 250.0 kgf·cm and 5.0 to 220.0 lbf·in.

How long should the battery be charged?

Charging takes less than 8 hours, and charging for more than eight hours should be avoided because overcharging can cause explosion, overheating or battery leakage.

What should I do if nothing is displayed after the instrument has not been used for a long time?

Connect the AC charger and press the SYSTEM RESET button on the side; after reset, set the measurement mode switch to TR and press CLEAR so the display shows 0.