The L-Band RF Switch is a device used for switching the main and standby channels of L-Band RF signals. It provides two-way RF signal level detection and two-way optical path level detection. When the main channel signal unit fails and has no RF signal or its level is lower than the preset switching value, the detection circuit realizes automatic switching to the standby channel unit through the single-chip microcomputer. If the fault is cleared, it will automatically return to the main channel unit.
This Chinese user manual describes the HS-HS-LNB-RF-2*1, an L-Band RF switch used to change over between a main and a backup channel for RF signals. The unit provides two RF level detectors and two optical level detectors; when the main channel fails or its level drops below the preset switching value, the detection circuit switches automatically to the backup channel through a microcontroller, and it returns to the main channel once the fault is cleared. An auto/manual switch on the panel also allows manual channel changeover, and fault conditions are shown by LEDs.
The manual lists the main technical specifications (frequency band, insertion loss, frequency response, isolation, switching threshold, supply voltage and operating temperature), describes the front and rear panel items from 1 to 14, and gives operating instructions for the alarm indicators and the manual/auto selection. It ends with notes on the alarm levels of the optical and RF inputs and a system connection diagram. This manual is written in Chinese.
| Operating frequency band | 950~2150 MHz |
|---|---|
| Insertion loss | <4 dB |
| Frequency response | 2 dB ± 1 dB |
| Isolation | >40 dB |
| Switching threshold range | <-45 dBm |
| Power supply | DC 13-20 V |
| Operating temperature | -20 to +65 °C |
It operates in the 950~2150 MHz band.
When the main channel unit has no RF signal or its optical level falls below the preset switching value, the detection circuit switches to the backup channel through a microcontroller, and returns to the main channel when the fault is cleared.
Set the Manual/Auto switch to the manual position, then set the channel switch (CH A/CH B) to CH B; the CH B indicator lights green.
The Manual/Auto switch is set to the auto position at the factory, and the device works on the main channel CH A.