DRD DRD265 to DRD1000 Refrigeration Dryer User Manual

This document is a user manual for a refrigeration dryer, which introduces the features and specifications of the product.


DRD DRD265 to DRD1000 Refrigeration Dryer User Manual - cover page
Brand
DRD
Category
Other products
Document type
User Manual
Language
English
Pages
67
File format
PDF
File size
1.5 MB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
3EFAE8D15573E8605A53E97BEE5E914F

About this manual

This user manual covers DRD refrigeration dryers for compressed air treatment, models DRD265, DRD325, DRD400, DRD500, DRD700, DRD800 and DRD1000. It is intended for end-user operations with closed panels and includes safety, transport, handling, inspection and storage information.

The manual also describes installation requirements, commissioning steps, control panel operation, maintenance, troubleshooting and appendix information. Installation topics include operating space, air-cooled and water-cooled versions, electrical connection and condensate drain connection.

What's inside

  • Safety
  • Introduction
  • Installation
  • Commissioning
  • Control
  • Maintenance
  • Troubleshooting
  • Appendix

Specifications

Condenser side clearanceAt least 3.94 inches (10 cm)
Pre-filter filtration3 micron or better
Pre-filter replacement intervalAt least once a year
Crankcase heater preheat time12 hours before starting
Cooling water temperatureAt least 50°F (10°C)
Cooling water pressure43.5-145 PSIg (3-10 barg)
Copper conductor temperature ratingAt least 140°F (60°C)
Supply circuit breakerDifferential thermal magnetic, IDn = 0.3 A, contact opening distance 3 mm
Water-cooled version availabilityNot for models DRD265-500

Frequently asked questions

How long must the crankcase heater be switched on before starting the dryer?

The crankcase heater must be switched on 12 hours before starting the dryer.

What pre-filter element is required at the dryer air inlet?

A pre-filter element for 3 micron filtration or better is required.

How much clearance is needed on the condenser side?

Leave at least 3.94 inches (10 cm) clearance on the condenser side.