This document describes the GRAVIMIX blending system from Ferlin Plastics Automation. The system is suitable for efficient and accurate dosing of dry and free-flowing thermoplastic materials.
This manual covers the Ferlin GRAVIMIX FGB gravimetric dosing-blending system (types FGB MECS, FLECS, 5, 10 and 25) from Ferlin Plastics Automation. It describes installation of the blender, software installation and com-port selection on a PC, start-up, controller operation, recipe editing, system settings, production monitoring and reports, parameter overview, maintenance and repair, and technical information. The system doses dry and free-flowing thermoplastic materials gravimetrically to a programmed recipe and is intended for injection-moulding, extrusion, blow-moulding and central-blending applications.
GRAVIMIX doses all material components exactly to the programmed recipe, so fluctuations in bulk density, particle size or flow properties have no effect on dosing accuracy, and it records exact material consumption for production cost calculation. The manual explains loadcell and weighbin calibration, dispense, mixer and production modes, regrind and stock silo control, alarm handling, printer and CSV output, and the safety measures plus the electric and pneumatic connections required for the machine.
| Power supply | 240V 50/60Hz (P+N+PE) and 400V 50/60Hz (3P+N+PE) |
|---|---|
| Compressed air supply | Minimum 6 bar, 1/4" BSP connection, clean and dry |
| Dosing accuracy | Up to ±0.1% |
| Maximum throughput | Up to 2500 kg/h with up to 10 stations |
| Dosing stations | Up to four stations, up to eight with slide valves for larger systems, plus one to two precision screw feeders |
| Material contact parts | Wear resistant stainless steel |
It is suitable for efficient and accurate dosing of dry and free-flowing thermoplastic materials, gravimetrically to the programmed recipe.
It achieves a total dosing accuracy up to ±0.1%, also for small quantities and extreme dosing conditions.
Up to four stations are used, and up to eight stations with slide valves for larger systems; one to two precision screw feeders can handle small quantities of free-flowing additives.
A 240V 50/60Hz (P+N+PE) or 400V 50/60Hz (3P+N+PE) power supply must be available before installation.