M9 touch screen period programming thermostat, weekly circulation, it is possible to set 6 periods called events each day with corresponding pre-set temperatures, also you can select "period control mode" or "manual mode" according to your individual requirements.
German Oshland Automatic Technology Co., Ltd. provides this installation manual for the M9 touch screen period programming thermostat. The document describes the M9.713, M9.723 and M9.716 models and their use for electric heating devices or on/off valve actuators in water-based heating systems.
The manual covers technical data, user operation, display symbols, six-event daily programming with pre-set temperatures, advanced settings, mounting steps and connecting diagrams.
| Voltage | AC230V 50~60Hz |
|---|---|
| Limitation range | 5 °C to 60 °C (factory setting 35 °C) |
| Temperature measurement accuracy | 0.5 to 10 °C adjustable; factory setting ±1 °C |
| Housing material | Anti-flammable PC |
| M9.713 current rating | 3 A |
| M9.716 current rating | 16 A |
It is recommended for control of electric heating devices or on/off valve actuators used in water-based heating systems.
The thermostat allows six periods, called events, each day with corresponding pre-set temperatures.
The limitation range is 5 °C to 60 °C, with a factory setting of 35 °C.