The document is an installation and operating manual for a gas furnace.
The Thermo Pride OMC-70 is a gas-fired or oil-fired downflow, direct-vent (sealed combustion) furnace. The manual is intended for installation in manufactured homes, modular homes/buildings, and site-construction residential single-story dwellings.
The Installation and Service Manual covers safety warnings and labels, general instructions and clearances, furnace specifications, installation, combustion air, gas and oil fuel piping, electrical wiring, burner installation and adjustment, flue gas combustion analysis, dealer maintenance and troubleshooting, user information, a replacement parts list, and warranty.
| Model | OMC-70 |
|---|---|
| Fuel type | Gas-fired or oil-fired |
| Vent configuration | Down flow and direct vent (sealed combustion) |
| Oil fuel | No. 1 and No. 2 fuel oil |
| Gas-fired test standard | UL 307B |
| Oil-fired test standard | UL 307A |
The manual covers the Thermo Pride OMC-70 gas-fired or oil-fired furnace.
It is intended for manufactured homes, modular homes/buildings, and site-construction residential single-story dwellings.
Thermo Pride oil furnaces are designed to burn commercial standards of No. 1 and No. 2 fuel oil; gasoline must never be used.
Do not use it; call a qualified service technician to inspect it and replace any electrical or control-system parts that were underwater.